TELLEZ, C. J. et al. Evaluation of two immunochromatography kits for rapid diagnosis of rotavirus infections. Rev. argent. microbiol. [online]. 2008, vol.40, n.3, pp.167-170. ISSN 0325-7541.
A prospective study was conducted to evaluate two immunochromatography (ICG) commercial kits for diagnosis of rotavirus infection, VIKIA® Rota-Adeno (bioMérieux) and Simple Rota-Adeno (Operon). Reverse transcriptase and polymerase chain reaction (RT-PCR) with specific primers for the VP7 gene of group A rotavirus was used as the reference method. The sensitivity and specificity of the ICG tests compared with those of the reference method were 98.4% and 84.8%, respectively, for Simple Rota-Adeno (Operon), and 100% and 24.2% for VIKIA® Rota-Adeno (bioMérieux). It is remarkable the low specificity of the latter method, which yields a high number of false positive results. The predictive value of a positive result by this method was only 71.6%. Most of the detected rotavirus strains corresponded to genotype G9P(8) (65%), followed by G1P(8) (25.4%) and G2P(8) (3.2%).
Palabras clave : Rotavirus; Immunochromatography; Rapid diagnosis; RT-PCR.