SciELO - Scientific Electronic Library Online

 
vol.80 número5Tratamiento antiagregante guiado por pruebas de función plaquetaria en pacientes sometidos a angioplastia coronaria exitosaCosto-efectividad de los stents liberadores de fármacos versus stents convencionales en el manejo de la enfermedad coronaria: Revisión sistemática de la bibliografía índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista argentina de cardiología

versión On-line ISSN 1850-3748

Resumen

MENDIZ, Oscar A et al. Outcomes of Direct Implantation of Self-Expandable Aortic Valve Prosthesis for Severe Aortic StenosisOutcomes of Direct Implantation of Self-Expandable Aortic Valve Prosthesis for Severe Aortic Stenosis. Rev. argent. cardiol. [online]. 2012, vol.80, n.5, pp.360-365. ISSN 1850-3748.

Objective To describe the initial experience with aortic valve implantation via a direct approach using a self-expanding CoreValveTM aortic valve prosthesis in a tertiary care center from Argentina. Material and methods From May to December 2010, 21 consecutive patients with severe aortic stenosis (SAS) and high surgical risk undergoing percutaneous aortic valve replacement with CoreValveTM prosthesis were included. The inclusion criteria were the following: aortic valve area <1 cm2 (<0.6 cm2/m2); aortic annulus diameter of 20-27 mm; diameter of the ascending aorta at the level of the sinotubular junction ≤ 40 (small prosthesis) or ≤ 43 mm (large prosthesis), and femoral artery diameter >6 mm. Results Mean age was 79±8 years, mean aortic valve area was 0.7±0.2 cm2 and mean logistic EuroSCORE was 26±15% (50% with logistic EuroSCORE ³ 20%). After valve implantation, peak transaortic pressure gradient measured by echocardiography decreased from 80±22 to 14±5 mm Hg. Two patients developed severe aortic regurgitation which improved with post-dilation. The success rate of the procedure was of 95% as a patient died immediately after valve implant. A definite pacemaker was implanted to six patients due to atrioventricular block. Cumulative survival was 75% after a mean follow-up of 5±2.8 months. Conclusion Our initial experience suggests that direct implantation of CoreValveTM prosthesis is a safe and feasible therapeutic option for patients with SAS and high surgical risk.

Palabras clave : Aortic Valve Stenosis; Catheterization; Endovascular procedures.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons