SciELO - Scientific Electronic Library Online

 
vol.77 número1Herpes zoster en adultos mayores en un hospital privado de la ciudad de Buenos Aires, junio 2013 - mayo 2014Carcinoma escamoso primario de órbita índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Journal

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Medicina (Buenos Aires)

versão impressa ISSN 0025-7680versão On-line ISSN 1669-9106

Resumo

MARTINUZZO, Marta E et al. Función renal y nivel plasmático de dabigatrán en el valle, medido por un ensayo de trombina diluida. Medicina (B. Aires) [online]. 2017, vol.77, n.1, pp.31-36. ISSN 0025-7680.

Dabigatran etexilate (direct thrombin inhibitor) is effective in preventing embolic stroke in patients with atrial fibrillation. It does not require laboratory control, but given the high renal elimination, its measurement in plasma is important in renal failure. The objectives of the study were to verify the analytical quality of the diluted thrombin time assay for measurement of dabigatran plasma concentration (cc), correlate cc with classic coagulation assays, prothrombin time (PT) and activated partial thromboplastin time (APTT), and evaluate them according to the creatinine clearance (CLCr). Forty plasma samples of patients (34 consecutive and 6 suspected of drug accumulation) receiving dabigatran at 150 (n = 19) or 110 (n = 21) mg/12 hours were collected. Blood samples were drawn at 10-14 hours of the last intake. Dabigatran concentration was determined by diluted thrombin time (HemosIl DTI, Instrumentation Laboratory (IL). PT and APTT (IL) were performed on two fotooptical coagulometers, ACL TOP 300 and 500 (IL). DTI presented intra-assay coefficient of variation < 5.4% and inter-assay < 6%, linearity range 0-493 ng/ml. Patients´ cc: median 83 (4-945) ng/ml. Individuals with CLCr in the lowest tertile (22.6-46.1 ml/min) showed significantly higher median cc: 308 (49-945), compared to the average 72 (12-190) and highest tertile, 60 (4-118) ng/ml. Correlation between cc and APTT or PT were moderate, r2 = 0.59 and -0.66, p < 0.0001, respectively. DTI test allowed us to quantify plasma dabigatran levels, both in patients with normal or altered renal function, representing a useful tool in clinical situations such as renal failure, pre surgery or emergencies.

Palavras-chave : Dabigatran; Plasma dabigatran measurement; Renal function.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )

 

Creative Commons License Todo o conteúdo deste periódico, exceto onde está identificado, está licenciado sob uma Licença Creative Commons