SciELO - Scientific Electronic Library Online

 
vol.108 issue3Obstructive sleep apneas in symptomatic obese children: polisomnographic confirmation and its association with disturbances in carbohydrate metabolismPortalhypertension in pediatrics. I: Pathophysiology and clinical aspects author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Archivos argentinos de pediatría

Print version ISSN 0325-0075On-line version ISSN 1668-3501

Abstract

COSTA, Christian Elías et al. Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry. Arch. argent. pediatr. [online]. 2010, vol.108, n.3, pp.234-238. ISSN 0325-0075.

Introduction. The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. Aim. To assess the accuracy of different methods to measure urine specific gravity. Methods. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. Results. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Conclusions. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

Keywords : Specific gravity; Reagent strips; Refractometer; Hydrometry.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License