SciELO - Scientific Electronic Library Online

 
vol.39 número2 índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

Compartir


Acta bioquímica clínica latinoamericana

versión impresa ISSN 0325-2957versión On-line ISSN 1851-6114

Resumen

MARIANI, Virginia Alcira  y  SOLA, María Ofelia. Program for external quality evaluation: differences in commercial inmunoassays of prostate-specific antigen. Acta bioquím. clín. latinoam. [online]. 2005, vol.39, n.2, pp.243-252. ISSN 0325-2957.

Due to the importance of the PSA (Prostate Specific Antigen) test the Program for External Quality Assessment (PEEC) of the FBA carried out five surveys among 200 laboratories. Five lots of lyophilized commercial serum with different degrees of PSA (ng/mL) were distributed among the participants and for each lot the Consensus Media (Mc), the Consensus Standard Deviation (SDc) and participants (N) were calculated: Lots 1, N1 = 272, Mc1 ± SDc1 = 2,6 ± 0,7; lot 2, N2=242, Mc2 ± SDc2 = 4,8 ± 1,2; lot 3, N3=128, Mc3 ± SDc3 = 8,1 ± 1,9; lot 4 N4=119, Mc4 ± SDc4 = 18,2 ± 4,5; lot 5, N5=262, Mc5 ± SDc5 = 55,7 ± 12,6. The results were useful to evaluate and compare nine commercial kits: Coat-A-Count and IMMULITE of Diagnostic Products Corporation®; IMX and AXSYM by Abbott®; ELFA by Bio-Merieux®; ELECSYS-1010 and 2010 by Roche®; ACS-180 by Bayer® and Access by Beckman®. The parameters evaluated were 1) Coefficient of Variation calculated as the quotient between the standard deviation and the media of each laboratory group using the same commercial trademark multiplied by 100 2) The Percentage of Relative Deviation (PRD) calculated as the distance between the obtained results of each laboratory and the media of each commercial equipo. The methods with the best behavior as regards the obtained CV were: AXSYM, ELFA, ELECSYS-1010, ELECSYS-2010, IMMULITE y ACCESS. Most of the participants using automatic methods, obtained better PRD in the different surveys compared to the laboratories using manual techniques. According to the test, it is not possible to compare results from laboratories using different methodologies.

Palabras clave : Program for External Quality Assessment; prostate specific antigen.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons