SciELO - Scientific Electronic Library Online

 
vol.76 número3Reubicación de los vasos del cuello y exclusión endovascular de las disecciones y los aneurismas del arco aórticoEvaluación de las placas coronarias por tomografía computarizada multidetector de 16 filas: Correlación con ecografía intravascular índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista argentina de cardiología

versión On-line ISSN 1850-3748

Resumen

MARENCHINO, Ricardo G. et al. Mid-term Follow-Up of Patients Submitted to Aortic Valve Replacement with Mechanical Prosthesis. Rev. argent. cardiol. [online]. 2008, vol.76, n.3, pp.187-192. ISSN 1850-3748.

Background Aortic valve disease is one of the most frequent causes of valve replacement in our environment. This study was performed based on the lack of information related to late outcomes in patients submitted to aortic valve replacement with mechanical prosthesis. Objective To assess the mortality, morbidity (major complications) and functional outcomes (clinical improvement) during the follow- up of patients with mechanical prosthesis placed in the aortic position. Material and Methods Ninety five patients submitted to aortic valve replacement with mechanical prosthesis were selected. Surgeries were performed between January 1999 and December 2006. Mean follow-up was 4±2.3 years; percentiles 25-75: 2.5-6.3 years. Total follow-up was 427.5 patients/year. Results Mean age was 64.5±12.3 years, 61.1% were men. Sixty patients (63%) were in functional class (FC) III-IV prior to surgery. During follow-up, 67 patients (70.5%) were en FC I and 28 (29.5%) in FC II. No patients presented FC III or IV. Mean effective valve area/body surface area was 1.06 cm2/m2. Actuarial survival (Kaplan-Meier) was 95% (95% CI 88-98%) at one year and 89% at 5 years (95% CI 76-95%). Nine deaths (9.5%) were related to this condition. The incidence of complications was as follows: thromboembolism 0.2% patient/ year, bleeding 2.3% patient/year, and endocarditis 0.7% patient/ year. Re-operation rate was 0.4% patient/year. Conclusions These results were similar to those reported in international series in terms of survival and major complications. The number of adverse events observed at mid-term is still high, as it is all around the world.

Palabras clave : Valve Prosthesis; Survival; Aortic Valve Stenosis; Aortic Valve Regurgitation.

        · resumen en Español     · texto en Español     · Español ( pdf ) | Inglés ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons