SciELO - Scientific Electronic Library Online

 
vol.82 issue5Clinical Profile of Patients with Hypertrophic Cardiomyopathy at a University HospitalPrimary Percutaneous Coronary Intervention in Acute Myocardial Infarction: Long-Term Predictors of Adverse Events author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista argentina de cardiología

On-line version ISSN 1850-3748

Abstract

FERNANDEZ, Horacio E. et al. Quality of Care for Acute Myocardial Infarction in Argentina: Observations from the SCAR (Acute Coronary Syndromes in Argentina) Registry. Rev. argent. cardiol. [online]. 2014, vol.82, n.5, pp.373-380. ISSN 1850-3748.

Introduction: Quality assessments help to quantify the gap between healthcare provision and what should be awarded. There are specific measurements on quality of medical care for myocardial infarction which standardize the quality information that every institution should determine for self-assessment and for comparison with others. Objective: The aim of this study was to analyze quality of care for myocardial infarction data in our country using the SCAR (Acute Coronary Syndromes in Argentina) Multicenter Registry. Methods: Quality of care data for myocardial infarction was analyzed in patients included in the database of the SCAR Multicenter Registry using definitions of the "ACC/AHA 2008 performance measures for adults with ST-elevation and non-ST-elevation myocardial infarction" document. Results: The study analyzed 751 myocardial infarction cases with complete data on quality indicators. Aspirin, betablockers, statins and angiotensin antagonists were used in nearly 90% of patients. The exception was clopidogrel which was used in 72.5% of patients not receiving mechanical reperfusion. Ventricular function was assessed during hospitalization in 90.2% of cases. A reperfusion strategy was used in 90.1% of ST-segment-elevation infarctions and less than 12-hour evolution. Door-to-balloon time was < 90 minutes in 50.8% of cases, while door-to-needle time was < 40.5%. Conclusions: Overall, there was high compliance to pharmacological and reperfusion treatments except in the use of clopidogrel without mechanical revascularization, and low compliance to the appropriate times of reperfusion therapy.

Keywords : Myocardial Infarction; Myocardial Reperfusion; Angioplasty Balloon; Coronary; Thrombolytic Therapy; Quality of Health Care.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License