SciELO - Scientific Electronic Library Online

 
vol.88 issue3Psychosocial aspects of the COVID-19 pandemic in the Mendoza populationRisks of Cardiovascular Disease Patients in Times of COVID-19. A Survey of the Argentine Foundation of Cardiology author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista argentina de cardiología

On-line version ISSN 1850-3748

Abstract

LOPEZ, CARLOS et al. Electrocardiographic Recording System and Wireless Transmission During the COVID-19 Pandemic. Rev. argent. cardiol. [online]. 2020, vol.88, n.3, pp.211-215. ISSN 1850-3748.  http://dx.doi.org/10.7775/rac.es.v88.i3.18000.

Background:

Some therapies used for COVID-19 can prolong the QT interval and produce severe arrhythmias. QT interval measured from a standard electrocardiogram (ECG) requires additional personnel and risk of infection. Novel technologies to obtain an ECG connected to smartphones provide an alternative for the evaluation of corrected QT interval (QTc).

Objective:

The aim of this study was to evaluate the feasibility of using a single-lead ECG device to measure the QT interval in patients with suspected or confirmed COVID-19 before receiving treatment with drugs that can prolong the QT interval.

Methods:

The ECG was obtained with a KardiaMobile (KM) device and transmitted to a smartphone. The ECG recordings were saved as pdf files and electronically submitted to the electrophysiology section which centralized the reception and assessed the measured QT and QTc intervals.

Results:

A total of 31 patients (mean age 61 years, range 20-95 years) with suspected COVID-19 enrolled for treatment with hydroxychloroquine, azithromycin, ritonavir or lopinavir were analyzed. The recordings could be read in all the cases and had to be repeated in two cases. The mean value of the QTc interval was 423 ms (range 380-457 ms) in men and 439 ms (range 391-540 ms) in women. The response time since the ECG recording was submitted for analysis was 11 min (range 1-155).

Conclusions:

The QTc interval could be measured from ECG recordings obtained with KM devices connected to a smartphone and transmitted to a centralized reading center in all patients.

Keywords : Coronavirus Infections; COVID-19; Arrhythmias, Cardiac; Smartphone; Mobile Applications; Electrocardiography, Ambulatory/instrumentation.

        · abstract in Spanish     · text in Spanish     · English ( pdf ) | Spanish ( pdf )