SciELO - Scientific Electronic Library Online

 
vol.17 número3Relevancia clínica, diversidad y variabilidad genética de distintas especies del género Mycobacterium índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista americana de medicina respiratoria

versión On-line ISSN 1852-236X

Resumen

BORSINI, Eduardo et al. Titulaciones de CPAP autoajustable domiciliarias y correlación entre un algoritmo automático y la fórmula de Hoffstein. Rev. am. med. respir. [online]. 2017, vol.17, n.3, pp.00-00. ISSN 1852-236X.

Introduction: Continuous positive airway pressure (CPAP) has proven to be effective in the treatment of obstructive sleep apnea/hypopnea syndrome (OSAHS). Effective pressure is traditionally acquired with a polysomnography (PSG). The performance of unconventional strategies, such as auto-adjusting positive airway pressure (APAP) and titration formulas (Tf) varies according to the population where they are applied. Objective: To describe the APAP titration and correlate the mean airway pressure (Meanp), the Effp and the Hoffstein and Mateika Tf pressure (Hofff). Results: We included 192 patients, 52 female (27%) and 140 male; age, 60.2 years old ± 11.7 and BMI (body mass index) of 33.8 ± 6.7 kg/m2. The apnea-hypopnea index (AHI) was: 33.1 ± 16.6 in females and 36.5 ± 16 in males (p > 0.24); and 190 cases (98.9%) had an AHI > 15 ev/hour. Mean compliance with APAP was: 380 minutes ± 101 in females and 370 ± 91.2 in males (p > 0.54). Less than 10% of the population presented unacceptability criteria. We found a correlation between the Meanp and the Effp; rho: 0.73 (95% CI [confidence interval] 0.57-0.84) p < 0.001. However, between the Effp and the Hofff β: 0.519 and r2: 0.269 (p < 0.001) there was an underestimation by Hofff: - 1.98 cm H2O (95% CI, 1.48-2.49) and intraclass correlation index: 0.60 (95% CI: 0.47-0.80) p < 0.0001. Conclusions: A high proportion of patients titrate at home with APAP without supervision and with acceptability criteria. We did not find a suitable correlation between the Hofff and the Effp in our population.

Palabras clave : Titration; CPAP; Hoffstein and Mateika.

        · resumen en Español     · texto en Español

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons