SciELO - Scientific Electronic Library Online

 
vol.33 issue2Effect of bleaching protocols on surface roughness and color change of high- and low-viscosity bulk-fill composite resinsEffect of preheating on cytotoxicity and physicochemical properties of light-cured calcium-based cements author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Acta Odontológica Latinoamericana

Print version ISSN 0326-4815On-line version ISSN 1852-4834

Abstract

BARREDA, Graciela J et al. Expansion treatment using Invisalign®: Periodontal health status and maxillary buccal bone changes. A clinical and tomographic evaluation. Acta odontol. latinoam. [online]. 2020, vol.33, n.2, pp.69-81.  Epub Sep 01, 2020. ISSN 0326-4815.

The aim of this study was to evaluate changes in periodontal status and maxillary buccal bone by considering clinical and tomographic parameters during the first year of orthodontic expansion with Invisalign® aligners. Upper first (1PM) and upper second (2PM) premolars of 19 patients with orthodontic expansion requirement treated with Invisalign® aligners were evaluated. Plaque index (PI), gingival index (GI), probing pocket depth (PPD), clinical attachment level (CAL) and cone beam tomographic (CBCT) records were collected at 76 sites before starting treatment (T0) and at 12 months (T1). Bone height was measured from cementoenamel junction (CEJ) to the crest cortical bone (CC). Bone thickness was measured at two levels: 4 mm (CEJ+4) and 6 mm (CEJ+6) apical to the CEJ. A descriptive analysis was made of the variations of bone thickness and height in a series of cases. The average expansion was 1.93 mm for 1PM and 167 mm for 2PM. Arithmetic mean of distance CEJ-CC in 1PM was 3.05 mm at T0, and remained at 3.05 mm at T1. Arithmetic mean of distance CEJ-CC in 2PM was 2.06 mm at T0 and 2.31 at T1. Post-expansion, most of the analyzed sites (86%) exhibited a bone thickness of ≥0.5 mm. The greatest variations between T0 and T1 were observed at the level of 1PM CEJ+ 4 and 2PM CEJ+ 6. The minimal changes in the clinical records (GI, PI, PPD and CAL) between T0 and T1 were compatible with the maintenance of gingivalperiodontal health. Invisalign® for expansion movements did not produce substantial changes in the evaluated periodontal clinical parameters or in the bone measurements. Removable appliances reduce plaque retentive factors and favor adequate oral hygiene.

Keywords : Clear aligner appliances; Periodontium; Cone beam computed tomography; Facial bones.

        · abstract in Spanish     · text in English     · English ( pdf )