SciELO - Scientific Electronic Library Online

 
vol.34 número2Evaluación clínica del recubrimiento radicular mediante colgajo desplazado coronal asociado a injerto dérmico acelular en recesiones únicasPrevalencia de primeros y segundos molares primarios mandibulares con tres raíces índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión impresa ISSN 0326-4815versión On-line ISSN 1852-4834

Resumen

GARCIA-CUERVA, Martín; BOAVENTURA-DUBOVIK, Agustina  y  IGLESIAS, María E.. Transmittance of lithium disilicate ceramic of different thicknesses and opacities with different curing units. Acta odontol. latinoam. [online]. 2021, vol.34, n.2, pp.143-148.  Epub 31-Ago-2021. ISSN 0326-4815.

The aim of this study was to evaluate the amount of radiating energy transmitted through lithium disilicate discs of different thicknesses and opacities with different curing units (CU). Discshaped specimens 8 mm in diameter and 1.5 mm or 0.7 mm thick were designed with Zbrush® and Cura 3D® software, milled from HT and MO IPS e-maxCAD blocks (Ivoclar Vivadent) with Ceramill Mikro 4 (Amann Girrbach, Austria) and processed according to manufacturer instructions. Thickness was checked with a Mitutoyo (México) caliper. Four groups (n=4) were formed: G1(HT/1.5 mm), G2(MO/1.5 mm), G3(HT/0.7 mm) y G4(MO/0.7 mm), and the effect of three CUs: Coltolux (Coltene- Whaledent), LED.C, (Woodpecker Medical Instrument Co.Ltd) and Deepcure L(3M-ESPE) was tested Measurements were taken with a halogen and LED radiometer (Woodpecker® LM-1-Guilin Woodpecker Medical Instrument Co.Ltd) after applying the guide of each CU directly on the reading window (d) and after interposing each of the specimens. The ratio of transmitted energy was determined in each case and data was analyzed with repeated measures ANOVA and Tukey test for multiple comparisons. LED.C: d:1600 mW/cm2, G1: 0.31(0.00), G2: 0.14(0.00) G3: 0.54(0.01), G4: 0.38(0.01); Deepcure L: d:1500 mW/cm2, G1: 0.34(0.01), G2: 0.20(0,00), G3: 0.56(0.01), G4: 0.41(0.02); Coltolux: d:1275 mW/cm2, G1: 0.44(0.01), G2: 0.24(0,00), G3: 0.65(0.01), G4: 0.47(0,00). Statistically significant differences were found among the curing units (P<0.001) and for the interaction CU-thickness (P<0.001) and CU-opacity (P=0.023). Within the conditions of this study, the ratio of light transmitted through lithium disilicate structures is related to their thickness and opacity, and to the curing unit employed.

Palabras clave : lithium disilicate; ceramics; dental curing light.

        · resumen en Español     · texto en Inglés     · Inglés ( pdf )