SciELO - Scientific Electronic Library Online

 
vol.34 número3Phagocytic activity of monocytes and neutrophils in patients with periodontitis, whether or not associated to type 2 diabetesPropiedades mecánicas y adhesión entre diferentes combinaciones composite Nanohíbrido-Bulkfill índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión impresa ISSN 0326-4815versión On-line ISSN 1852-4834

Resumen

SANTOS-NETO, Oswaldo S et al. Retention of cemented zirconia copings on TiBase abutments. Acta odontol. latinoam. [online]. 2021, vol.34, n.3, pp.214-220.  Epub 31-Dic-2021. ISSN 0326-4815.  http://dx.doi.org/10.54589/aol.34/3/214.

This study evaluated the influence of resin cements and glass ionomers on tensile strength and types of failure of zirconia copings cemented on titanium base abutments. Forty-two samples were prepared, which were formed by a Cone Morse implant, a titanium abutment with the fixing screw, and a zirconia structure made using a CAD/CAM system. The samples (n = 42) were randomly distributed according to the cementing agent: resin-modified glass ionomer cement (RelyX Luting 2), self-adhesive resin cement (RelyX U200), and self-curing resin cement (Multilink N). After cementation of the copings, half of the samples from each group (n = 7) were randomly selected and subjected to thermocycling (5000 cycles). A tensile load test was performed on a universal testing machine until failure occurred (1 mm). In addition, the type of failure was analyzed using the two-way analysis of variance test and Tukey’s post-hoc test (α = 0.05). Lower tensile load was observed for the glass ionomer cement (p < 0.001) regardless of the evaluation period. After thermocycling, a significant reduction in tensile load values was verified for both evaluated cements (p = 0.047). For the resin cements, failures were predominantly of the screw fracture type (82.1%) already with the use of glass ionomer cement, and 28.5% of the failures were of an adhesive type between the zirconia coping and the cement. Resin cements have better stability under tensile load compared to resin glass ionomers when cementing zirconia copings on titanium base abutments.

Palabras clave : prostheses and implants; dental implant; ceramics; resin cements; glass ionomer cements; dental implant abutment interface.

        · resumen en Portugués     · texto en Inglés     · Inglés ( pdf )