GARROFE, Analía B; PICCA, Mariana  and  KAPLAN, Andrea E. Determination of microhardness of bulk-fill resins at different depths. Acta odontol. latinoam. [online]. 2022, vol.35, n.1, pp.10-15.  Epub Apr 30, 2022. ISSN 0326-4815.  http://dx.doi.org/10.54589/aol.35/1/10.

The aim of this study was to determine Vickers microhardness (HV) in bulk fill resins at different depths. Test specimens were prepared with different bulk fill resins: Filtek Bulk-Fill (3M ESPE) [FBF], Surefill SDR flow (Dentsply) [SDR], Fill-UP (COLTENE) [FU] and Surefill (Dentsply) [SF]. Semi-cylindrical test specimens were prepared in a mold 6 mm in diameter and 4 mm thick (n=5). A 1000 mW/cm2 light curing unit was applied (Coltolux LED - Coltene) for 20 seconds. HV was determined with three indentations (Vickers Future Tech FM300, 300 g, 8 s) at four depths: 1, 2, 3 and 4 mm from the top surface to the interior. Data were recorded immediately (t0) and 24 hours later (t24). Results were analyzed with two-way ANOVA (p<0.05), and multiple comparisons were performed using Tukey’s test. Mean and SD of HV at t0 for each mm were: [FBF] t0: 49.23(4.65) / 48.32(3.36) / 44.38(2.06) / 40.59(2.58); [FBF] t24: 61.37(3.47) / 62.63(3.03) / 57.27(5.22) / 56.37(5.88); [SDR] t0: 27.81(3.13) / 28.07(2.4) / 27.24(2.94) / 25.71(3.0); [SDR] t24: 35.11(2.16) / 35.17(1.96) / 35.53(1.81) / 33.18(2.08); [FU] t0: 41.43(1.41) / 39.87(0.88) / 38.11(1.81) / 39.09(1.92); [FU] t24: 49.27(1.54) / 48.77(1.77) / 48.65(1.88) / 46.76(4.93); [SF] t0: 71.35(7.09) / 67.39(9.76) / 68.95(6.21) / 64.1(8.35); [SF] t24: 76.06(6.61) / 75.31(9.37) / 75.2(11.57) / 69.81(12.14). ANOVA showed significant effect of material, depth and recording time (p<0.05), and Tukey’s test showed that recording sites (depths) differed significantly, giving four homogeneous groups. Under the conditions of this study, it can be concluded that microhardness of bulk-fill resins can be affected by depth and post-curing time.

Keywords : hardness; composite resins; hardness test.