SciELO - Scientific Electronic Library Online

 
vol.36 issue2gDNA extraction from Candida albicans and Candida dubliniensis in subgingival samples in Argentina. Evaluation of different methods author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Acta Odontológica Latinoamericana

Print version ISSN 0326-4815On-line version ISSN 1852-4834

Abstract

SILVA JUNIOR, Eduardo V; BASTING, Roberta T; TURSSI, Cecilia P  and  FRANCA, Fabiana MG. Precision of polyether ether ketone (PEEK) or cobalt-chrome implant bar fit to implants after mechanical cycling. Acta odontol. latinoam. [online]. 2023, vol.36, n.2, pp.71-77.  Epub Aug 31, 2023. ISSN 0326-4815.  http://dx.doi.org/10.54589/aol.36/2/71.

Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants. Aim: The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics. Materials and Method: This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey’s test at 5% significance level. Results: No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups. Conclusions: The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.

Keywords : PEEK; Dental prosthesis; Mouth rehabilitation.

        · abstract in Portuguese     · text in English     · English ( pdf )