SciELO - Scientific Electronic Library Online

 
vol.81 issue2Fracturas alrededor de una osteosíntesis extramedular previa de fémur proximal: Una solución simple para un problema complejoCambios en la lordosis lumbar luego de una artrodesis vertebral posterior de la columna torácica y su relación con la incidencia pelviana author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Journal

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista de la Asociación Argentina de Ortopedia y Traumatología

On-line version ISSN 1852-7434

Abstract

GARABANO, German; MANA PASTRIAN, Diego S  and  DEL SEL, Hernan. Revisiones de cadera en defectos oseos femorales Paprosky II y IIIA: Utilizacion de protesis no cementada, modular, de fijacion proximal y anclaje distal. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2016, vol.81, n.2, pp.115-121. ISSN 1852-7434.

Background: The purpose of this retrospective analysis was to observe the outcomes of a modular hip system in revision total hip arthroplasty with Paprosky types II and IIIA femoral bone defects, evaluating their performance, offset restoration and leg length discrepancy correction. Methods: Twenty-two revision total hip arthroplasties were analyzed in 12 women and 10 men (average age 62.38 years). The average follow-up was 62 months. Femoral stems S-ROMR (Depuy, Johnson & Johnson) were used. Paprosky femoral bone deficit were 15 types II and 7 IIIA. Clinical evaluation was performed using the Harris Hip Score, while Engh classification was used for stem fixation. Offset restoration, leg length discrepancy (a difference <5 mm was considered correct) and hip stability were evaluated radiographically. Results: Offset was properly restored in 16 (72.3%) cases and the leg length was matched in 15 (68.2%). There was a single stem subsidence and according to Engh classification, proximal bone ingrowth fixation was obtained in 17 (77.27%) patients. There were 7 (31.8%) complications: two dislocations that required revision, four intraoperative fractures and a lateral popliteal nerve paresis. Conclusions: S-ROMR modular system seems to be a valid alternative to solve a complex problem. Its versatility allows to optimize hip stability, leg length equalization and offset restoration in revision total hip arthroplasty, showing an acceptable complication rate.

Keywords : Revision; Total hip arthroplasty; Modular uncemented femoral stem; Proximal fixation; Offset; Leg length discrepancy; Joint stability.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License