SciELO - Scientific Electronic Library Online

 
vol.83 número1Uso topico de acido tranexamico en el reemplazo total de rodilla primarioEstudio histopatológico en rotura aguda del ligamento cruzado anterior de rodilla índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista de la Asociación Argentina de Ortopedia y Traumatología

versión On-line ISSN 1852-7434

Resumen

LOPREITE, Fernando; GARABANO, Germán; PESCIALLO, César  y  DEL SEL, Hernán. Artroplastia de cadera luego de una osteosíntesis fallida en fracturas laterales de cadera. Rev. Asoc. Argent. Ortop. Traumatol. [online]. 2018, vol.83, n.1, pp.12-19. ISSN 1852-7434.

Introduction: The purpose of this retrospective study was to assess the clinical and radiological outcomes, complications, and technical problems of total hip arthroplasty following failure of dynamic screw fixation of the intertrochanteric fractures. Methods: Thirty-eight total hip arthroplasties in 38 patients were reviewed (31 women and 7 men, with a mean age of 75.5 9 years [range 67-90]), with a follow-up of 45.5 months (range 16-128). Thirty were total hip arthroplasties, 7 bipolar hip arthroplasties and an unconventional prosthesis. Nine large femoral stems and 29 standard stems were used. The presence of pain was clinically evaluated, and the Harris hip score was objectively used. Quality of cementation (Barrack), prosthetic demarcations, loosening, pseudoarthrosis of the greater trochanter and its complications were analyzed in X-rays. Results: Average Harris Hip Score was 79 points (range 70-88). Thirty of 35 cemented femoral stems were type A (Barrack), 4 type B and one type C. There were no revisions. Four cemented cotyles had a demarcation line in zone I, one, in zones II and III; and the other in the three zones. There were 5 nonunion of greater trochanter, 3 acute infections with favorable outcome after toilette and antibiotics. Three patients suffered dislocations, one of them needed revision. Conclusions: Total hip arthroplasty as salvage procedure after failed dynamic screw fixation achieves acceptable functional results and allows ambulation. This procedure is technically challenging with a high complication rate.

Palabras clave : Intertrochanteric fracture; DHS; Failed internal fixation; Total hip arthroplasty.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons