SciELO - Scientific Electronic Library Online

 
vol.77 número4Optimización del uso de las imágenes en la patología suprarrenal (parte 2)qEsclerosis tuberosa: evaluación de las lesiones intracraneanas índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista argentina de radiología

versión On-line ISSN 1852-9992

Resumen

SURUR, A.M et al. Valoración no invasiva de la estenosis carotídea de causa aterosclerótica: correlación entre la ecografía Doppler color y la angiografía por resonancia magnética con gadolinio. Rev. argent. radiol. [online]. 2013, vol.77, n.4. ISSN 1852-9992.

Introduction: Carotid angiography is used to confi rm carotid bifurcation (CB) stenosis. However, it is an invasive method that involves some morbidity. For this reason there is growing interest in non-invasive methods for the evaluation of carotid stenosis, including magnetic resonance angiography with gadolinium (MRAG) and color Doppler ultrasound (USDC). The aim of this study is to determine the correlation between the color Doppler ultrasound and magnetic resonance angiography with gadolinium in the evaluation of the degree of stenosis. Materials and methods: One hundred carotid bifurcations were studied by color Doppler ultrasound and magnetic resonance angiography with gadolinium between January 2009 and August 2011 in Sanatorio Allende. The level of agreement was determined using the Kappa coeffi cient, analyzing the percentage of carotid stenosis with color Doppler ultrasound according to the maximum systolic speed and the stenosis seen by magnetic resonance angiography with gadolinium, using the NASCET criteria for both methods. Results: An excellent correlation was obtained between Doppler ultrasound and magnetic resonance angiography with gadolinium, with a Kappa coeffi cient of 0.90 (95% CI: 0.786-0.99). There was disagreement between the two methods in assessing the plaque surface, showing that magnetic resonance angiography with gadolinium was better for detecting an irregular surface and / or ulcerated plaque. Conclusion: The technological improvement and the increase in reliable studies that have a good diagnostic correlation with non-invasive methods, it could be assumed that, in a short period of time, Doppler ultrasound will gradually replace angiography in the diagnosis of carotid pathology.

Palabras clave : Stenosis; Internal carotid artery; Color Doppler ultrasound; Magnetic resonance angiography with gadolinium.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons