Superior Vena Cava Syndrome and Infectious Endocarditis Associated with Dual Chamber ICD Implantation
Síndrome de vena cava superior y endocarditis infecciosa asociado al implante de DAI bicameral
JAVIER URMENETA ULLOA, ISABEL MOLINA BORAO, MARUAN CHABBAR BOUDET
These images correspond to a 68-year-old male patient with a history of posteroinferior myocardial infarction, and out-of-hospital cardiopulmonary arrest due to an episode of ventricular fibrillation in November 2012, resuscitated without sequelae. The electrocardiogram showed inferoposterior hypokinesis with preserved LVEF. Coronary angiography ruled out significant lesions. After completing the study, a dual-chamber automatic cardioverter defibrillator (AICD) was indicated.
Six months after implantation, the patient presented with progressive symptoms of facial and cranial congestion, head-ache, and redness primarily associated with decubitus. CT scan and phlebography confirmed the diagnosis of superior vena cava syndrome (SVCS) due to significant stenosis. Initially, the approach was anticoagulant therapy and follow-up of the clini-cal course. During that period, the patient had self-limited fever bouts together with diaphoresis and chills, and was admitted with suspected endocarditis. The echocardiography showed an image consistent with vegetation on the ventricular lead. Blood cultures were positive for Staphylococcus epidermidis. Complete removal of the device was necessary due to poor clinical course -despite anticoagulant therapy (developing facial and upper tho-racic edema)- and a diagnosis of endocarditis on the defibrillator lead. However, symptoms consistent with SVCS persisted and a second phlebography confirmed persistent severe stenosis at that level (Figure 1). In that scenario, percutaneous stent implanta-tion in the SVC was performed without complications (Figure 2), followed by new AICD implantation in the contralateral tho-racic region via the right subclavian artery, inserting a single lead through the implanted stent. Clinical course was favorable, and the patient is currently asymptomatic.
The incidence of SVCS in patients with cardiac electronic de-vices is very low (0.03-0.4%). (1) Predisposing factors include hy-percoagulability, use of hormone therapy, multiple leads, systemic infection, and use of polyurethane wires. (2) Patients are usually asymptomatic because slow progression of the disease allows time for collateral circulation to develop. However, its absence may result in florid and invalidating symptoms, as was the case of our patient. Treatment is controversial, and many authors claim that the use of anticoagulation is the first therapeutic option. If the course is unfavorable, other treatment options should be consid-ered, such as balloon angioplasty and stent implantation. (2, 3)
The association of several risk factors facilitates the devel-opment of SVCS. Our patient had two of the main factors associ-ated with this syndrome: the endovascular implantation of two leads and the underlying infection in one of them.
Given the clinical and prognostic implications of both enti-ties, we should always bear in mind this potential association in order to obtain a quick and accurate diagnosis, and apply an appropriate therapeutic strategy.
Conficts of interest
None declared
(See authors' conflict of interest forms in the web/ Supplemen-tary Material).
Rev Argent Cardiol 2015;83:551. http://dx.doi.org/10.7775.rac.v83.i6.6968
Address for reprints: Dr. Javier Urmeneta Ulloa - Calle Félix Latassa, 28, 6to C - 50006, Zaragoza, España - e-mail: javierurmeneta@hotmail.com
Department of Cardiology, Hospital Universitario Miguel Servet, Zaragoza Zaragoza, Spain
Fig. 1. Phlebography following device removal, confrming the persistent stenosis at the superior vena cava.
Fig. 2. Stent implantation in the superior vena cava.