SciELO - Scientific Electronic Library Online

 
vol.22 número1Effect of chewing gums on the production of volatile sulfur compounds (VSC) in vivo índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Acta odontol. latinoam. vol.22 no.1 Buenos Aires abr. 2009

 

ARTÍCULOS ORIGINALES

The issue of corrosion in dental implants: a review

 

Daniel G. Olmedo1, Déborah R. Tasat2, Gustavo Duffó3, María B. Guglielmotti1 and Rómulo L. Cabrini4

1 Department of Oral Pathology, School of Dentistry, University of Buenos Aires. National Research Council (CONICET). Argentina.
2 School of Science and Technology, National University of San Martin, Buenos Aires, Argentina.
3 Department of Materials, National Atomic Energy Commission, National Research Council (CONICET) and National University of San Martin, Buenos Aires, Argentina.
4 Department of Oral Pathology, School of Dentistry, University of Buenos Aires and Department of Radiobiology, National Atomic Energy Commission, Buenos Aires, Argentina.

CORRESPONDENCE Dr. Daniel Gustavo Olmedo. Department of Oral Pathology, School of Dentistry, University of Buenos Aires. Marcelo T. de Alvear 2142 2° “A” Buenos Aires C1122 AAH, Argentina. Tel: 5411 4964-1273 Fax #: 5411 45083958 e-mail: dolmedo@argentina.com


ABSTRACT

Pure titanium or titanium alloys, and to a lesser extent, zirconium, are metals that are often used in direct contact with host tissues. These metallic biomaterials are highly reactive, and on exposure to fluid media or air, quickly develop a layer of titanium dioxide (TiO2) or zirconium dioxide (ZrO2). This layer of dioxide forms a boundary at the interface between the biological medium and the metal structure, determining the degree of biocompatibility and the biological response of the implant. Corrosion is the deterioration a metal undergoes as a result of the surrounding medium (electrochemical attack), which causes the release of ions into the microenvironment. No metal or alloy is entirely inert in vivo. Corrosion phenomena at the interface are particularly important in the evolution of both dental and orthopedic implants and one of the possible causes of implant failure after initial success. This paper comprises a review of literature and presents results of our laboratory experiments related to the study of corrosion, with special emphasis on dental implants. In situ degradation of a metallic implant is undesirable because it alters the structural integrity of the implant. The issue of corrosion is not limited to a local problem because the particles produced as a result could migrate to distant sites, whose evolution would require further studies.

Key words: Corrosion; Dental implants; Macrophages; Failures.

RESUMEN

La problemática de la corrosion en implantes odontologicos

El titanio puro o en aleacion, y en menor grado el circonio, son los metales mas utilizados en contacto directo con los tejidos del  huésped. Estos biomateriales metálicos son muy reactivos y al exponerse a medios líquidos o al aire, desarrollan rápidamente una capa de dióxido de titanio (TiO2) o de dioxido de circonio (ZrO2). Esta capa de dióxido limita la interfase entre el medio biológico y la estructura metalica, determinando el grado de biocompatibilidad y la respuesta biológica del implante. La corrosión es el deterioro que sufre un metal debido al medio que lo rodea (ataque electroquímico) y que produce como consecuencia la liberación de iones en el microambiente. In vivo ningun metal o aleacion es completamente inerte. Los fenómenos de corrosión, en la zona de la interfase, son de especial importancia en la evolución de los implantes tanto odontológicos como ortopédicos y constituyen una de las posibles causas de fracaso de un implante luego del éxito inicial. El presente trabajo comprende una revision bibliográfica y la presentación de resultados de las experiencias de nuestro laboratorio en relación al estudio de la corrosión con especial énfasis en los implantes odontológicos. La degradación “in situ” de un implante metálico es un hecho no deseable ya que altera la integridad estructural del implante. La problemática de la corrosión no se limitaría a un problema local dado que las partículas resultantes de este proceso podrían migrar a sitios alejados al sitio del implante, cuya evolución plantea interrogantes para futuros estudios.

Palabras clave: Corrosion; Implantes odontologicos; Macrofagos; Fracasos.


 

INTRODUCTION

The discovery of relatively inert metallic and alloy biomaterials has led to their use in the field of biomedical applications such as orthopedics and dentistry. They are being increasingly used due to their physical-chemical properties and compatibility with biological surroundings1. Pure titanium or titanium alloys, and to a lesser extent, zirconium, are the metals that are most often used in direct contact with host tissues. These metallic biomaterials are highly reactive and when exposed to fluid media or air, quickly develop a layer of titanium dioxide (TiO2) or zirconium dioxide (ZrO2). This layer of dioxide forms a boundary at the interface between the biological medium and the metal structure. It produces passivation of the metal, determining the degree of biocompatibility and the biological response of the implant2-4. Titanium dioxide exists naturally mainly in the form of three crystalline structures: rutile, anatasa and brookite. In titanium implants, the passivant oxide layer is made up of anatasa and rutile or anatasa alone5,6.
The use of titanium dental implants has revolutionized oral implantology. In the USA, about 300,000 patients a year currently receive dental implants1. With the aim of improving their biocompatibility and mechanical resistance, their manufacture attempts to achieve adequate design and minimum degradation, corrosion, dissolution, deformation and fracture. Corrosion is the deterioration of a metal as a result of the surrounding medium (electrochemical attack), which causes ions to be released into the microenvironment 7 . There are “noble” metals such as rhodium (Rd), palladium (Pd), iridium (Ir) and platinum (Pt), which owe their resistance to corrosion to high thermodynamic stability. Metals known as passivable, such as titanium (Ti), vanadium (V), zirconium (Zr), niobium (Nb) and tantalum (Ta), are thermodynamically unstable and owe their resistance to corrosion to the formation of a protective surface layer of oxide8
.
No metal or alloy is entirely inert in vivo. Corrosion is one of the possible causes of implant failure after initial success. Therefore, management and control of corrosion is a crucial problem from biological, metallurgical en economic standpoints. Corrosion should be analyzed with an interdisciplinary focus and the participation of chemists, biologists, physicists, engineers, metallurgists and biomedical specialists. The issue of corrosion has been researched at the Biomaterials laboratory at the Department of Oral Pathology of the School of Dentistry of Buenos Aires University, together with the National Commission of Atomic Energy and National University of San Martin. Research focuses on the assessment of local tissue response in the peri-implant microenvironment and the systemic effects and possible consequences of the process of corrosion, with special emphasis on dental implants.

STUDIES ON THE LOCAL EFFECT OF CORROSION

The interface between the implant and its periimplant tissues is assessed in situ by means of systematic histological studies at the Biomaterials Laboratory, which has a Failed Dental Implant Service. At the implant-tissue interface bone tissue (osseointegration), medullary tissue (myelointegration), fibrous tissue and/or inflammatory reactions can be found. At the lab, human dental implant failure is most often caused by mobility, metal fracture (fatigue) or early exposure9. It is worth noting that the interface of implants that have failed due to metal fatigue are found to have good osseointegration. In this case, the implant is successful from a biological standpoint (osseointegration) but a clinical failure from the mechanical standpoint. Guglielmotti and Cabrini9 found metal particles included in the osseointegrated bone tissue and the bone medulla of implants that failed due to metal fatigue, providing evidence of the corrosion of the metallic structure. Olmedo et al.10 found macrophages loaded with metal particles as indicators of the corrosion process in the soft peri-implant tissue of failed human dental implants (Fig. 1 A-B). Microchemical analysis of the particles contained in the macrophages, determined by x-ray dispersion (EDX) analysis, confirmed the presence of titanium. It is worth noting that the number of loaded macrophages was greater in the proximity of metal surface of implants than at a distance from it.


Fig. 1A
: Failed human dental implant showing tissue in contact
with the metallic surface and tissue fragments obtained by curettage of the surgical bed.


Fig. 1B
: Photomicrograph of macrophages near the surface of the implant. Note the presence of particles in their cytoplasm. Ground section. Orig. Mag. X1000.

In the field of oral and maxillofacial surgery, titanium is widely used as an implant in the form of membranes, grids, reduction plates, screws and distractors, among others. According to the literature, the removal of titanium miniplates once the bone has healed is usually considered unnecessary precisely because of titanium’s excellent biocompatibility and resistance to corrosion. This is beneficial for the patient, who need not undergo a second surgical procedure11. Furthermore, some maintain that the mini-plates should only be removed if they cause complaints and in cases of wound dehiscence or infection11. However, as mentioned above, no metal or alloy is entirely inert in vivo. In this regard, some authors claim that titanium miniplates should be removed, to allow for physiologic bony adaptation and avoidance of a foreign body reaction11-15. Thus, whether or not titanium mini-plates or grids should be removed after the bone has healed is still a matter of controversy. We have conducted experimental assessment of the biological effect of a type of localized corrosion – pitting – in the peri-implant environment16. From a histological standpoint, we found little osseointegration with extensive zones of soft tissue in the metal-tissue interface and the presence of corrosion products in the peri-implant environment, especially surrounding the blood vessels, to be drained by them (Fig. 2). Local adverse effects produced by this kind of corrosion and observed in this study suggest caution in the use of titanium plates and grids as permanent fixation structures. Corrosion phenomena at the interface are especially important in the evolution of both dental and orthopedic implants.


Fig. 2
: Blood vessel in the bone marrow near an experimental implant surface and products of corrosion (→) in the vicinity. Ground section. Orig. Mag. X1000.

The issue of corrosion may not be limited to a local problem because particles produced as a result of corrosion may migrate to sites far from the implant. This subject is of particular interest in studies of biocompatibility.

DISSEMINATION OF TITANIUM TO OTHER BIOLOGICAL COMPARTMENTS

The local effect of corrosion with the consequent passage of metal particles to the peri-implant biological medium may also compromise other biological compartments. In the field of orthopedics there are data that state that titanium ions pass into the surrounding tissues, reach the inner medium and are excreted in urine17. Different researchers have found metal ions in body fluids and organs. Galante et al.17 studied osseointegrated coxofemoral prostheses made from titanium 90% - aluminum 6% - vanadium 4%, showing that ions of all three metals pass into the plasma and are excreted in urine. In autopsies, Urban et al. found metal and plastic particles from coxofemoral prostheses and knee replacements in organs such as liver, spleen and lymph nodes18.
As previously described, titanium and zirconium implants have a protective surface layer of dioxide (TiO2 or ZrO2). This layer is responsible for biocompatibility and forms a boundary of the interface between the biological medium and the implant, reducing its reactivity and partially preventing corrosion3,4,7. With the aim of assessing the pathways of the dissemination of corrosion products and estimating the
how much is deposited in different biological compartments, we have developed experimental models using animals which are subject to intraperitoneal injection of TiO2 or ZrO2 19-24. During these experiments we made histological observations and quantified titanium and zirconium deposits in organs with macrophagic activity such as liver (Fig. 3), spleen and lung19. For equivalent doses and times there was always more titanium deposited than zirconium. In addition, we found titanium or zirconium particles in monocytes (Fig. 4) and blood plasma22,24.


Fig. 3
: Rat liver. Note the abundant presence of titanium
deposits in the parenchyma of the organ of an animal injected with TiO2. Grenacher carmine stain. Orig. Mag. X400.


Fig. 4
: Rat blood smear. Titanium particles are evident in a peripheral blood monocyte. Safranin stain. Orig. Mag. X1000.

The detection of titanium or zirconium in the blood (cells and/or plasma) of patients with prostheses (coxofemoral, dental, plates and screws for fracture reduction, metal plates for reconstruction of large zones) could be used as an indicator of the presence of a corrosion process of the metal structures. It is known that traces of metal can increase the physiological production of reactive oxygen species (ROS), which, without a compensatory increase in antioxidant species, leads to tissue damage25-27. We have proved the presence of titanium and zirconium particles in lung phagocytes identified immunohistochemically as CD68 macrophages28. The evaluation of the oxidative metabolism of lung macrophages exposed to these oxides shows an increase in ROS generation. Nevertheless, it should be noted that ROS levels in animals exposed to ZrO2 are markedly lower than the levels found in animals exposed to TiO2. The data suggest that zirconium is more biocompatible than titanium23,24.

CLINICAL IMPLICATIONS OF CORROSION

It is concluded from the analysis of failed human dental implants and the information obtained from experimental models that any titanium surface might undergo a process of corrosion with particles passing into the local biological and systemic medium. Biochemical changes in the peri-implant microenvironment can lead to corrosion of the implant. In traumatized tissues significant drops in pH values have been found, reaching values as low as pH 4 during the healing process29. These values greatly increase the aggressiveness of tissues towards metallic materials. We have found that the reduction of pH in the electrolytic medium as a consequence of local inflammatory processes may also act as a corrosion-stimulating agent30. The corrosion process may limit the metal’s resistance to fatigue, compromising its resistance, which may eventually cause the fracture of the implant31-34. It has been reported that saliva leaking between the suprastructure (nickel-chrome-molybdenum alloy) and the implant (made of pure titanium) may trigger a corrosion process (galvanic corrosion) due to differences in electrical potential. This generates the passage of ions such as nickel or chrome from the alloy of a crown or bridge to the peri-implant tissues, with consequent bone reabsorption and may compromise the mobility of the implant and its subsequent fracture31.
The release of ions/particles may produce pigmentation of the soft tissues adjacent to an implant (metallosis) 35. In one experiment we made a histological assessment of tissue response in human oral mucosae associated to submerged titanium implants, using biopsies of human oral mucosae from the area covering the implant’s closure screw. That study identified particles of different sizes, either free or taken up by macrophages, in the connective tissue (Fig. 5). In addition, scanning electron microscope
images showed depressions and irregularities on the surface of metal caps. It would be interesting to relate possible biological action of these particles with the evolution of the implant36. The products of corrosion of the metal implant may behave as haptenes, generating a hypersensitivity reaction with release of inflammatory mediators known as cytokines and macrophage recruitment37-39. It has not yet been proved whether hypersensitivity to metal is the cause of implant failure or vice versa37. Similarly controversial is the issue of whether an inflammatory process is responsible for corrosion, or corrosion triggers an inflammatory process. Furthermore, metal corrosion can affect the close contact between the implant and the bone tissue. Metal particles from coxofemoral prostheses can be ingested by macrophages, stimulating the release of cytokines that contribute to bone reabsorption by activating osteoclasts. In addition to increasing bone reabsorption, these particles can suppress the osteoblast function, reducing bone formation and contributing to osteolysis40,41.


Fig. 5
: Human oral mucosa that covered an implant closure screw. Note the presence of free titanium particles or particles phagocytosed by macrophages at the epithelium-chorion interface (→). H-E. Orig. Mag. X1000.

Titanium toxicology is a subject currently under discussion. According to epidemiological studies, inhalation of environmental dust containing titanium does not have a deleterious effect on lungs42,43 but other studies have suggested the association of titanium particles with pleural pathologies44, granulomatous diseases and malignant lung neoplasm45. The accumulation of metal particles in the liver might compromise its function, as described by Urban et al. in a study where the presence of titanium particles in a patient was associated to granulomatous reactions and hepatomegaly18. In experimental models, we have observed the presence of a considerable amount of titanium particles not only in macrophages but also in hepatocytes28. It has been reported that some of the metals currently used most often in the manufacture of implants, particularly in the field of orthopedics (titanium, aluminum, vanadium, cobalt, chrome, nickel) are potentially toxic46-51. Their carcinogenic potential has been assessed in experimental studies on animals52-54. Nevertheless, there are few reports on the possible development of malignant tumors associated to prosthetic structures in humans2,55,56. In this regard, our work group has reported one case of sarcomatous degeneration in the proximity of a stainless steel metal prosthesis, with the aim of contributing with the pool of information to help define more certainly the potential toxicity and risks associated to the use of metallic implants57. It is interesting to note that the International Agency for Research on Cancer (IARC) has recently classified TiO2 as a possible human carcinogen58.
“In situ” degradation of a metallic implant is undesirable because it alters the structural integrity of the implant. Implant manufacturing prospects aim at developing methods that will help reduce the passage of ions/particles from implants to tissues, in order to minimize the adverse effects of corrosion. We believe that further studies are needed, in particular long-term studies, to continue defining the factors involved in implant corrosion and to establish the basic conditions for their use in clinical implantology. It is important to stress that the adverse effects of corrosion described in this paper do not always occur in patients with implants, because the biological response varies among individuals.

AKNOWLEDGEMENTS

This study was supported by the grants: BID 1728/OC-AR - PICT 33493 from the National Agency for the Promotion of Science and Technology, O-020 from University of Buenos Aires, CONICET PIP6042 and Roemmers Foundation, Argentina.

REFERENCES

1. Ratner BD, Hoffman AS, Schoen FJ, Lemons JE. Biomaterials Science: A Multidisciplinary Endeavor, In: Ratner, B.D., Hoffman A.S., Schoen, F.J. and Lemons, J.E. (eds), Biomaterials Science. An Introduction to Materials in Medicine. Second edition (2004), Introduction, pp. 1-9, Elsevier Academic Press, San Diego, California, USA.         [ Links ]

2. Kasemo B, Lausmaa J. Biomaterial and implant surfaces: A surface science approach. Int J Oral Maxillofac Implants 1988;3:247-259.         [ Links ]

3. Kasemo B. Biocompatibility of titanium implants: Surface science aspects. J Prosthet Dent 1983;49(6):832-837.         [ Links ]

4. Long M, Rack HJ. Titanium alloys in total joint replacement: A materials science perspective. Biomaterials 1998; 19(18):1621-1639.         [ Links ]

5. Effah E, Bianco PB, Ducheyne P. Crystal structure of the surface of oxide layer on titanium and its changes arising from immersion. J Biomed Mater Res 1995;29:73-80.         [ Links ]

6. Sul YT, Johansson CB, Jeong K, Roser K, Wennerberg A, Albrektsson T. Oxidized implants and their influence on their bone response. J Mater Sci Mater Med 2001;12:1025- 1031.         [ Links ]

7. Jacobs JJ, Gilbert JL, Urban RM. Current concepts review - Corrosion of metal orthopaedic implants. J Bone and Joint Surg 1998;80(2):268-282.         [ Links ]

8. Lucas L, Lemons J. Biodegradation of restorative metallic systems. Adv Dent Res 1992;6:32-37.         [ Links ]

9. Guglielmotti MB, Cabrini RL. Evaluacion biologica de implantes dentales fracasados. Rev Asoc Odontol Argent 1997;85(4):313-317.         [ Links ]

10. Olmedo D, Fernandez MM, Guglielmotti MB, Cabrini RL. Macrophages related to dental implant failure. Implant Dent 2003;12:75-80.         [ Links ]

11. Rosenberg A, Gratz KW, Sailer HF. Should titanium miniplates be removed after bone healing is complete? Int J Oral Maxillofac Surg 1993;22:185-188.         [ Links ]

12. Young-Kyun K, Hwan-Ho Y, Seung-Cheul L. Tissue response to titanium plates: A transmitted electron microscopic study. J Oral Maxillof Surg 1997;55:322-326.         [ Links ]

13. Ferguson AB, Laing PG, Hodge ES: The ionization of metal implants in living tissues. J Bone Joint Surg 1970;42:77-90.         [ Links ]

14. Moran CA, Mullick FG, Ishak KG, Johnson FB, Hummer WB. Identification of titanium in human tissues: Probable role in pathologic processes. Hum Pathol 1991;22:450-454.         [ Links ]

15. Katou F, Andohn N, Motegui K, Nagara H. Inmuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures. J Craniomaxillof Surg 1996;24:155-162.         [ Links ]

16. Olmedo DG, Duffo G, Cabrini RL, Guglielmotti MB. Local effect of titanium implant corrosion: an experimental study in rats. Int J Oral Maxillofac Surg 2008;37(11):1032-1038.         [ Links ]

17. Jacobs J, Skipor AK, Urban J, Galante RM. Release and excretion of metal in patients who have a total hip replacement component made of titanium base alloys. J Bone Joint Surg 1991;73:1475-1486.         [ Links ]

18. Urban R, Jacobs J, Tomlinson M, Gavrilovic J, Black J, M. Peoc’h M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone and Joint Surg 2000;82[A]: 457-476.

19. Olmedo D, Guglielmotti MB, Cabrini RlL. An experimental study of the dissemination of titanium and zirconium in the body. J Mater Sci: Mater Med 2002;13:793-796.         [ Links ]

20. Cabrini RL, Olmedo D, Tomasi V, Guglielmotti MB. Microincineration for the detection of titanium in tissue sections. J Histotech 2002;25:75-78.         [ Links ]

21. Cabrini RL, Olmedo D, Guglielmotti MB. A quantitative method to evaluate corrosion products in tissues. Acta Odontol Latinoamer 2003;16:27-33.         [ Links ]

22. Olmedo DG, Tasat DR, Guglielmotti MB and Cabrini RL. Titanium transport through the blood stream. An experimental study on rats. J Mater Sci Mater Med 2003;14(12): 1099-1103.         [ Links ]

23. Olmedo D, Tasat DR, Guglielmotti MB, Cabrini RL. Effect of titanium dioxide on the oxidative metabolism of alveolar macrophages: An experimental study in rats. J Biomed Mater Res Part A 2005;73(2):142-149.         [ Links ]

24. Olmedo D, Tasat D, Evelson P, Guglielmotti MB, Cabrini RL. Biological response of tissues with macrophagic activity to titanium dioxide. J Biomed Mater Res Part A 2008; 84(4):1087-1093.         [ Links ]

25. Maziere C, Floret S, Santus R, Morliere P, Marcheux V, Maziere JC. Impairment of the EGF signaling pathway by the oxidative stress generated with UVA. Free Radic Biol Med 2003;34(6):629-636.         [ Links ]

26. Kawanishi S, Oikawa S, Inoue S, Nishino K. Distinct mechanisms of oxidative DNA damage induced by carcinogenic nickel subsulfide and nickel oxides. Environ Health Perspect 2002;15:789-791.         [ Links ]

27. Gottschling BC, Maronpot RR, Hailey JR, Peddada S, Moomaw CR, Klaunig JE, Nyska A. The role of oxidative stress in indium phosphide-induced lung carcinogenesis in rats. Toxicol Sci 2001;64(1):28-40.         [ Links ]

28. Olmedo D, Tasat D, Guglielmotti MB, Cabrini RL. Biodistribution of titanium dioxide from biologic compartments. J Mater Sci Mater Med 2008;19(9):3049-3056.         [ Links ]

29. Laing PG. Compatibility of biomaterials. Orthop Clin of NA 1973;4(2):249-273.         [ Links ]

30. Duffo G, Barreiro M, Olmedo D, Crosa M, Guglielmotti MB, Cabrini RL. An experimental model to study implant orrosion. Acta Odont Latinoamer 1999;12:3-10.         [ Links ]

31. Tagger Green N, Machtei EE, Horwitz J, Peled M. Fracture of dental implants: Literature review and report of a case. Implant Dent 2002;11(2):137-143.         [ Links ]

32. Guindy JS, Schiel H, Schmidli F, Wirz J. Corrosion at the marginal gap of implant-supported suprastructures and implant failure. Int J Oral Maxillofac Implants 2004;19(6):826-831.         [ Links ]

33. Nikolopoulou, F. Saliva and dental implants. Implant Dent 2006;15(4):372-376.         [ Links ]

34. Adya N, Alam M, Ravindranath T, Mubeen A, Saluja B. Corrosion in titanium dental implants: literature review. J Indian Prosthodont Soc 2005;5:126-131.         [ Links ]

35. Black J, Sherk H, Bonini J, Rostoker WR, Schajowicz F, Galante JO. Metallosis associated with a stable titaniumalloy femoral component in total hip replacement. A case report. J Bone Joint Surg [Am] 1990;72(1):126-130 .         [ Links ]

36. Olmedo DG, Paparella ML, Brandizzi D, Spielberg M, Cabrini RL. Response of oral mucosa associated to titanium implants [abstract] 2007; J Dent Res 86, Spec Iss Letter B: 83, (www.dentalresearch.org).         [ Links ]

37. Hallab N, Merrit K, Jacobs J. Metal sensitivity in patients with orthopaedic implants. Current concepts review. J Bone Joint Surg [Am] 2001;(83)3:428-436.         [ Links ]

38. Yang J, Merrit K. Detection of antibodies against corrosion products in patients after Co-Cr total joint replacements. J Biomed Mater Res 1994;28:1249-1258.         [ Links ]

39. Jiranek WA, Machado M, Jasty M, Jevsevar D, Wolfe HJ, Goldring SR, Goldberg MJ, Harris WH. Production of citokines around loosened cemented acetabular components. Analysis with inmunochemical techniques and in situ hybridization. J Bone Joint Surg [Am] 1993;75(6):863-879.         [ Links ]

40. Dowd JE, Schwendeman LJ, Macaulay W, Doyle JS, Shanbhag AS, Wilson S, Herndon JH, Rubash HE. Aseptic loosening in uncemented total hip arthroplasty in canine model. Clin Orthop 1995;319:106-121.         [ Links ]

41. Allen MJ, Myer BJ, Millet PJ, Rushton N. The effects of particulate cobalt, cromium and cobalt-chromium alloy on human osteoblast-like cells in vitro. J Bone and Joint Surg 1997;79-B(3):475-482.         [ Links ]

42. Daum S, Anderson HA, Lilis R, Lorimer W, Fischbein SA, Miller A, Selikoff IJ. Pulmonary changes among titanium workers [abstract]. Proc Roy Soc Med 1977;70:31-32.         [ Links ]

43. Ferin J, Oberdorster G. Biological effects and toxicity assessment of titanium dioxides: anatase and rutile. Am Indust Hyg Assn J 1985;46:69-72.         [ Links ]

44. Garabrant DH, Fine LJ, Oliver C, Bernstein L, Peters JM. Abnormalities of pulmonary function and pleural disease among titanium metal production workers. Scandinavian J Work Environ and Health 1987;13:47-51.         [ Links ]

45. Lee K, Henry NW, Trochimowicz HJ, Reinhardt CF. Pulmonary response to impaired lung clearance in rats following excessive TiO2 dust deposition. Environ Res 1986;41:144-167.         [ Links ]

46. Elinder CG, Friberg L. Cobalt. In: Friberg L, Nordberg GF and Vouk VB, eds. Handbook of the toxicology of metals. Amstertdam: Elsevier, 1986;2:211-232.         [ Links ]

47. Gitelman, HL. Aluminium and health: A critical review. New York: Marcel Dekker, 1989.         [ Links ]

48. Jandhyala BS, Hom GJ. Minireview. Physilogical and pharmacologycal properties of vanadium. Life Sci 1983; 33:1325-1340.         [ Links ]

49. Langard S, Norseth, T. Chromium. In: In: Friberg L, Nordberg GF and Vouk VB, eds Handbook of the toxicology of metals. Amsterdam, Elsevier, 1986, vol 2: 185-210.         [ Links ]

50. Sunderman FW. A pilgrimage into the archives of nickel toxicology. Ann Clin Lab Sci 1989;19:1-16.         [ Links ]

51. Williams DF. Biological effects of titanium. In: Williams DF, ed. Systemic aspects of biocompatibility. Boca Raton. Florida: CRC Press, 1981;169-177.         [ Links ]

52. Hueper, WC. Experimentals studies in metal carcinogenesis. I. Nickel cancers in rats. Texas Rep Biol and Med 1952; 10:167-186.         [ Links ]

53. Lewis CG, Sunderman FW, Jr: Metal carcinogenesis in total joint arthroplasty. Animal models. Clin Orthop 1996;329: 264-268.         [ Links ]

54. Sinibaldi K, Rosen H, Liu SK, DeAngelis M: Tumors associated with metallic implants in animals. Clin Orthop 1976; 118:257-266.         [ Links ]

55. Brown SA, Merrit K, Farnsworth LJ, Crowe TD. Biological significnace of metal ion release. In: Lemon JE, ed. Quantitative characterizacion and performance of porous implants for hand tissue applications. Philadelphia: American Society fot Testing and Materials, 1987;163-181.         [ Links ]

56. Black J. Editorial. Does corrosion matter? J Bone Joint Surg [Br] 1988;70:517-520.         [ Links ]

57. Olmedo D, Michanie E, Olvi L, Santini-Araujo E, Cabrini RL. Malignant fibrous histiocytoma associated to coxofemoral arthrodesis. Tumori 2007;93:504-507.         [ Links ]

58. Baan R, Straif K, Grosse Y, Secretan B, El Ghissassi F, Cogliano V. Carcinogenicity of carbon black, titanium dioxide and talc. Lancet Oncol 2006;7:295-296.         [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons