vol.24 número1Relationship among metabolic control, oral parameters and self-efficacy in diabetic patientsInfluence of occlusal stabilization splints and soft occlusal splints on the electromyographic pattern, in basal state and at the end of six weeks treatment in patients with bruxism índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Acta odontol. latinoam. vol.24 no.1 Buenos Aires abr. 2011

 

ARTÍCULOS ORIGINALES

Condensation silicones: do new materials really presents better dimensional stability?

 

Juliene C. Fonte-Boa1, João Maurício L.F. Mota1, Luiz Thadeu A. Poletto1, Maria Carmen F.S. Carvalho1, Maria Esperanza Cortés1, Rubén D. Sinisterra2, Sophia F. Leal1

1Department of Restorative Dentistry, School of Dentistry, Minas Gerais Federal University, Belo Horizonte, Brazil.
2Department of Chemistry, Institute of Sciences , Minas Gerais Federal University, Belo Horizonte, Brazil.

CORRESPONDENCE Dra. Juliene Caetano Fonte Boa Faculdade de Odontologia, UFMG, Antonio Carlos 6627, Belo Horizonte, 31270-901 Brasil jufonteboa@uol.com.br


ABSTRACT

The aim of this study was evaluate the dimensional stability of some condensation silicones. The following materials were studied: Coltex/ColtoflaxR - Coltene, SpeedexR - Coltene, and Optosil Comfort/Xantopren VL PlusR - Kulzer. They were evaluated by dimensional analysis and gas chromatography (GC) performed at the following times: T0, T1, T2, T3, T4, and T5 (immediately after setting, thirty minutes, two hours, twenty four hours, seventy two hours, and seven days after setting, respectively). The dimensional changes were measured directly in the molds using a Mitutoyo microscope. The ColtexR fine/ColtoflaxR and OptosilR Comfort/XantoprenR VL Plus materials presented dimensional stability for up to thirty minutes after molding, while the SpeedexR material remained stable for up to two hours after molding. The gas chromatography experiment demonstrated that these materials release ethanol even after clinical setting.

Key words: Dental Impression Materials; Polydimethylsiloxane; Gas Chromatography.

RESUMO

Siliconas de condensação: novos produtos realmente apresentam melhor estabilidade dimensional?

Com o intuito de avaliar a estabilidade dimensional de algumas siliconas de condensacao, foi realizada uma analise dimensional e um teste de cromatografia gasosa dos seguintes materiais: Coltex/ColtoflaxR - Coltene, SpeedexR - Coltene e Optosil Comfort / Xantopren VL PlusR - Kulzer. Tanto as medidas de alteracao dimensional quanto a cromatografia gasosa foram feitas nos seguintes tempos: T0, T1, T2, T3, T4 e T5 (imediatamente apos a presa, trinta minutos, duas horas, vinte e quatro horas, setenta e duas horas e sete dias apos a presa, respectivamente). A alteracao dimensional foi medida diretamente nos moldes em um microscopio comparador. As medidas de alteracao dimensional demonstraram que os materiais ColtexR fine/ColtoflaxR e OptosilR Comfort/Xantopren R VL Plus apresentaram estabilidade dimensional por ate trinta minutos apos a moldagem, enquanto o material SpeedexR apresentou-se estavel por ate duas horas apos a moldagem. O experimento de cromatografia gasosa demonstrou que esses materiais liberam etanol mesmo apos a presa clinica.

Palavras-chave: Materiais de Moldagem odontologicos; Polidimetilsiloxano; Estabilidade Dimensional; Cromatografia Gasosa.


 

INTRODUCTION

The properties, indications, and clinical procedures recommended for each impression material must be known and observed by dentists in their own clinical practices in order to obtain precise molds. Dimensional stability determines the time interval at which the plaster should be poured over the mold. Among the impression materials, those that polymerize without by-products (addition silicones and polyethers) have greater dimensional stability, given that the molds made from these materials can be cast up to seven days after molding. In contrast, molds cast using materials that polymerize by condensation (polysulfides and condensation silicones), should be poured within the first 30 minutes after molding, considering that by-products are generally released during storage. In Brazil, according to findings Mello et al.1 and Almeida et al.2, 78% of all dental professionals choose to adopt condensation silicones even though they may present a lower level of dimensional stability. This demonstrates that the advantages of the materials that polymerize by addition were not enough to eliminate the use of condensation silicones on the market. Such behavior justified the appearance of two condensa- tion silicones on the market (SpeedexR- Coltene and OptosilR Comfort/XantoprenR VL Plus - Hearaeus Kulzer), which provide a prolonged dimensional stability, given that the molds can be stored for up to seven days with no loss in precision.
The dimensional stability announced by manufacturers has raised condensation silicones to a higher level in this property, reaching the level of materials that polymerize by addition. But, to the best of our knowledge, there are few studies that prove the differential behavior of the new silicones, which would be essential to allow an effective comparison among products available on the market. In this light, the aim of this study is to evaluate the dimensional stability of these materials by means of measurements carried out directly within the molds, stored at different times and check, by means of Gas Chromatography (GC), whether or not ethanol is released during the same storage times.

MATERIAL AND METHODS

The dimensional stability analysis was carried out on OptosilRComfort / XantoprenR VL Plus - Kulzer, SpeedexR- Coltene and ColtoflaxR/ ColtexR fine- Coltene materials, by means of direct measurements of molds using a Mitutoyo microscope. The molds were obtained by molding a master plate to a perforated plate tray, using the double molding technique. The plate tray contained perforations to retain the molding material and to fit into two different positions on the plate tray in such a way as to supply a 2.00 mm space for the first molding, using putty material, and a 4.00 mm space for the second molding, using light material (Fig. 1).


Fig. 1:
Plate tray and master plate in two different positions to supply a 2.00 mm space for the dense material impression (a, b) and a 4.00 mm space for the second molding (c, d) using fluid and dense materials.

On the master plate, two parallel lines were drawn with a 10.0 mm space between them. Next, five more lines were drawn perpendicular to the first lines. The distances between the intersection points were then measured. The materials were proportioned and manipulated according to manufacturer instructions. During the molding process, the plate trays were maintained in position manually, and the fittings on the master plate guaranteed the most appropriate position. The setting time for putty materials was 4 minutes, while that for light materials was 8 minutes, at which time the plate tray was manually removed. The molds adhered to the plate trays during the entire study. Measurements were performed using a MITUTOYO microscope, in triplicate, by two trained observers at six times intervals: T0, T1, T2, T3, T4, and T5 (immediately after setting, 30 minutes, 2 hours, 24 hours, 3 days, and 7 days after the setting). During the measurement intervals, the bodies-of-evidence were stored at an average temperature of 25°C.
In the present study, as calculated in a pilot study, the number of bodies-of-evidence needed was eight for each material. The percentage of dimensional change was calculated by the following formula:

%= 100 x L1 – L2 /L2

In which L1 represents the measurement (mm) at time T0, and L2 represents the measurement (mm) at the times to be compared (T1, T2, T3, T4, or T5), which is similar to the calculation formulated by Fano, Gennari and Ortalli3.
The Kruskall Wallis non-parametric test (significance 0.05) was used to compare the materials at the different analysis times. To compare the times studied for each material, the Friedman test (significance 0.05) was used, while the Wilcoxon test (significance 0.003) was used to identify the differing time intervals among them4,5. The GC was applied to the putty and light polymerized materials in an attempt to detect the release of ethanol from the samples at times T0, T1, T2, T3, T4, and T5. The silicones were proportioned by weight, manipulated, and spread on 6 X 1 cm glass plates, which were placed inside hermetically sealed tubes (VaccuetR), with
an appropriate location set in the rubber for needle puncture. Six plates and six tubes, one for each analysis time, were used for each material. The tubes were stored at room temperature of approximately 25°C and heated to 50°C for five minutes before extraction. The analyses were carried out in a VARIAN CP-3380 Gas Chromotagraph, Column: SE30 30m x 0.25mm (Alltech), with the following temperatures: Column: 50°C, 5 min; Injector: 100°C, split 1/100; Detector FID: 100°C; and an injection volume of 500μl. The carrier gas used was hydrogen at a flow rate of 2ml/min.

RESULTS AND DISCUSSION

In the dimensional analysis, the Kruskall Wallis test demonstrated the p-values (0.377; 0.369; 0.504; 0.599; 0.911; 0.653 respectively at times T0, T1, T2, T3, T4, and T5). Therefore, all materials studied presented a similar behavior during the storage of their respective molds, i.e., they underwent dimensional changes. The Friedman test detected differences among the six times of interest for each material (p-values = 0.000). The average percentage of dimensional change obtained for the measurements of all intersections of the molds is presented in Fig 2.


Fig. 2:
The average percentage of dimensional change obtained for three materials, at times T1, T2, T3, T4 and T5 ( 30 minutes, 2 hours, 24 hours, 3 days and 7 days after setting) in relation to T0 ( immediately after setting).

The negative values in the graph represent expansion, while the positive values represent contraction. From time T0 to the molding storage time of 30 min (T1), expansion was observed in the ColtexR fine/ ColtoflaxR material, contraction in the OptosilR Comfort/ XantoprenR VL Plus material, yet practically no dimensional change in the SpeedexR material was observed. For the three materials studied, the Wilcoxon statistical test demonstrated that no significant difference in this storage time was observed (p-values 0.129; 0.150; 0.536 for ColtexR fine/ColtoflaxR, OptosilR Comfort/ XantoprenR and SpeedexR respectively). Thus, all materials can have their molds stored for 30 minutes before casting the models. From 30 min to 2 h storage, all materials contracted. According to the Wilcoxon test, the dimensional change in the measurements taken immediately after molding (T0) up to 2 h of storage (T2) was considered to be statistically significant for the OptosilR Comfort/ XantoprenR VL Plus and ColtexR fine/ ColtoflaxR materials (p-value 0.000). The SpeedexR material did not show the same outcome (p-value 0.044). Accordingly, only the SpeedexR material molds can be stored for up to 2 h after molding, with no loss of precision. As of 24 h, significant statistical differences were observed between T0 and all other storage times for all materials studied (p-value 0.000). It is therefore not recommended to cast models in up to 7 days using OptosilR Comfort/XantoprenR VL Plus and SpeedexR materials, as laid out in manufacturer instructions. In addition, the materials presented characteristics of different dimensional behavior, which reinforces the report by Craig et al. 6 that despite generalizations made about the properties of the different types of elastomeric impression materials not all of the products of the same type and class possess the same qualities. Thus, the material should be selected based on experimental values and not on the general type of molding materials. For Chen SY et al.7, the choice of material is the factor which could most affect precision. In addition, dimensional changes are caused mainly by reactions among components. The safest time to cast models for the ColtexR fine/ColtoflaxR and OptosilR Comfort/ XantoprenR VL Plus materials continues to be up to 30 min maximum, as reported in the literature by a great majority of authors for condensation silicones8- 13. In contrast, the SpeedexR molds can be stored for up to 2 hours with no loss of precision. These results are in agreement with findings from Guimaraes et al. 14 and Nishioka et al. 15.
Of the materials studied, the ColtexR fine/ColtoflaxR materials presented the lowest level of dimensional stability, with diverse changes of both contraction and expansion. A delay in the molding process using these materials can bring about greater consequences concerning the precision of the models. Brown 16 listed a number of factors that may affect the dimensional stability and precision of the molding materials, among which are thermal effects stemming from the difference between the temperature of the oral cavity and room temperature, the tissue’s absorption of water while taking the impression, and the elastic recovery, mainly when molding retentive areas. Brown considers that these factors often occur concurrently, making it difficult to individualize the contribution of each as regards dimensional changes. In the present case study, only two factors mentioned by Brown regarding dimensional factors were actually observed: continuing polymerization and the loss of volatile constituents after polymerization, during storage of the molds, which is also supported by the findings of Fano, Gennari, and Ortalli3. According to the literature, the main reason behind the low dimensional stability of the condensation silicones lies in the formation of ethyl alcohol as a byproduct during the polymerization reaction, which may continue even after the setting of the material. Thus, the evaporation of the by-product, and the consequent contraction due to polymerization, would remain continuous1,13,17-19.
The results of the GC are shown in Fig 3 and 4. These graphs show that ethanol was released from all materials at the evaluated times. The putty materials released less ethanol than the light materials. This outcome was expected, given that the quantity of the polymeric matrix is proportionally lower due to the quantity of the load added to it to provide an appropriate working consistency, Anusavice13, Craig and Powers20 emphasized that the putty materials would undergo a lesser level of polymerization contraction than would the light materials, due mainly to the load added to these materials. The values obtained using the GC technique did not comply with a defined release standard. One possible explanation is the absorption of ethanol by the polymer, or even the imprisonment of ethanol in the polymeric mass, hindering its release within the tubes. This premise is consistent and may well explain the expansion found in the dimensional analysis for the Coltex R fine/ColtoflaxR material at the time intervals of T0 to T1, as well as for the other two silicones studied at the final storage times. The results of this study demonstrate that there is no mandatory contraction during the storage of condensation silicones; however, a dimensional change is observed, which may cause the loss of precision of the prosthetic work should there be a delay in the pre-set times for modeling.


Fig. 3:
Ethanol release (ppm) from fluid materials, at times T0, T1, T2, T3, T4 and T5.


Fig. 4:
Ethanol release (ppm) from dense materials, at times T0, T1, T2, T3, T4 and T5.

CONCLUSIONS

Production of ethanol in the polymerization of condensation silicones is observed, even after their clinical setting.
The ColtexR fine/ColtoflaxR and OptosilR Comfort/ XantoprenR VL Plus materials presented dimensional stability for up to 30 minutes. Thus, they should be modeled within a maximum of 30 minutes after molding. Modeling of SpeedexR material can be delayed for up to two hours after molding.

REFERENCES

1. Mello EB, Silva EF, Siqueira APB, Souza DM, Reif GA, Carneiro IL et al. Estabilidade dimensional das siliconas de condensacao. Revista do CROMG 2002; 8: 20-24.         [ Links ]

2. Almeida EES, Kimpara ET, Nishioka RS, Bottino MA, Neisser MP. Estudo da alteracao dimensional em silicones para moldagem polimerizados por reacao de condensacao. Rev Fac Odontol Bauru 2002; 10: 275-281.         [ Links ]

3. Fano V, Gennari PU, Ortalli I. Dimensional stability of silicone- based impression materials. Dent Mater 1992; 8: 105-109.         [ Links ]

4. Campos H. Estatistica Experimental Nao-Parametrica. Piracicaba: Departamento de Estatistica e Matematica – ESALQ/ USP. 1979.

5. Siegel S, Castellan Jr NJ. Estatistica nao-parametrica para ciencias do comportamento. Porto Alegre: Editora Artmed; 2006.         [ Links ]

6. Craig RG, Urquiola NJ, Liu CC. Comparison of commercial elastomeric impression materials. Oper Dent 1990; 15:94-104.         [ Links ]

7. Chen SY, Liang WM, Chen FN. Factors affecting the accuracy of elastomeric impression materials. J Dent 2004; 32: 603-609.         [ Links ]

8. Stackhouse JA. The accuracy of stone dies made from rubber impression materials. J Prosthet Dent 1970; 24: 377- 385.         [ Links ]

9. Lacy AM, Bellman T, Fukui H, Jendresen MD. Timedependent accuracy of elastomers impression materials. Part I: Condensation silicones. J Prosthet Dent 1981; 45: 209-215.         [ Links ]

10. Ciesco NJ, Malone WFP, Sandrik JL, Mazur B. Comparison of elastomeric impression materials used in fixed prosthodontics. J Prosthet Dent 1981; 45: 89-94.         [ Links ]

11. Tjan AHL, Whang SB, Tjan AH, Sarkissian R. Clinically oriented evaluation of the accuracy of commonly used impression materials. J Prosthet Dent 1986; 56: 4- 8.         [ Links ]

12. Craig RG, Sun Z. Trends in elastomeric impression materials. Oper Dent 1994; 19: 138-145.         [ Links ]

13. Anusavice KJ. Materiais de moldagem elastomericos nao - aquosos. In: Phillips Materiais Dentarios. Rio de Janeiro: Editora Guanabara Koogan; 1998. p. 83-106.         [ Links ]

14. Guimaraes JGA, Neto PC, Correa I, Muench A, Grande R. Avaliacao da estabilidade dimensional de um novo elastomero para moldagem.(Abstract) In: 15a Reuniao Anual da Sociedade Brasileira de Pesquisa Odontologica, 1998: 102. Aguas de Sao Pedro; Sao Paulo; Brasil.         [ Links ]

15. Nishioka RS, Almeida EES, Andreatta Filho OD, Balducci I. Avaliacao entre um silicone de polimerizacao por adicao e outro por condensacao. Rev Odontol. UNESP 2000; 29: 93-104.         [ Links ]

16. Brown D. Factors affecting the dimensional stability of elastic impression materials. J Dent 1973;1: 265-274        [ Links ]

17. Asgar K. Elastic Impression Materials. Dent Clin North Am 1971; 15: 81-98.         [ Links ]

18. Farah JW, Clarck AE, Ainpour PR. Elastomeric Impression Materials. Oper Dent 1981; 6:15-19.         [ Links ]

19. Wilson HJ. Impression Materials. Br Dent J 1988; 164: 221-225.         [ Links ]

20. Craig R G, Powers, J. Impression materials. In: Dental Materials. Ed. Mostby; 2000. p.138- 78.         [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons