SciELO - Scientific Electronic Library Online

 
vol.25 número3Odontogenic cell culture in PEGDA hydrogel scaffolds for use in tooth regeneration protocolsFunctional impairment in submandibular gland of rats induced by 5-fluorouracil and calcium leucovorin índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Acta odontol. latinoam. vol.25 no.3 Buenos Aires dic. 2012

 

ARTÍCULOS ORIGINALES

Effect of disinfectant solutions on a denture base acrylic resin

 

Cristiane F. Carvalho, Aleska D. Vanderlei, Susana M. Salazar Marocho, Sarina M. B. Pereira, Lafayette Nogueira, Tarcisio J. Arruda Paes-Junior

Department of Dental Materials and Prosthodontics São Paulo State University, São José dos Campos, Brazil.

CORRESPONDENCE Dr. Tarcisio Jose de Arruda Paes Junior Faculdade de Odontologia de Sao Jose dos Campos - UNESP Av .Engenheiro Francisco Jose Longo, 777, CEP 12245-000 Jardim Sao Dimas, Sao Jose dos Campos, Sao Paulo, Brazil E-mail: tarcisio@fosjc.unesp.br


ABSTRACT

The aim of this study was to evaluate the hardness, roughness and mass loss of an acrylic denture base resin after in vitro exposure to four disinfectant solutions. Forty specimens (Classico, Brazil) were prepared and randomly assigned to 4 groups (n=10) according to the disinfectant solution: G1: control, stored in distilled water at 37°C; G2: 1% sodium hypochlorite; G3: 2% glutaraldehyde; G4: 4% chlorhexidine. G2 to G4 were immersed for 60 minutes in the disinfectant solution. Measurements were carried out both before and after immersion in the solution. The surface was analyzed with a surface roughness tester (Surfcorder SE 1700 KOZAKALAB), a microdurometer FM-700 (Future Tech) and a scanning electron microscope (DSM 962-ZEISS). Loss of mass was determined with a digital weighing scale. After disinfection procedures, values were analyzed statistically. The acrylic denture base resin may be vulnerable to surface changes after in vitro immersion in the disinfectant solutions studied.

Keywords: Acrylic resins; Disinfection; Hardness; Roughness.

RESUMEN

Efecto de soluciones desinfectantes sobre prótesis con base de resinas acrílicas

El objetivo de este estudio fue evaluar la microdureza, rugosidad y perdida de masa de resinas acrilicas para base de dentadura despues de su exposicion a soluciones desinfectantes in vitro. Cuarenta especimenes de resina acrilica para base de dentadura (Classico, Brasil) fueron confeccionados y asignados randomizadamente a 4 grupos (n=10) segun la solucion desinfectante: G1: control, almacenado en agua destilada a 37 °C; G2: 1% hipoclorito de sodio; G3: 2% Glutaraldehido; G4: 4% clorhexidina. Los especimenes fueron inmersos por 60 minutos en la solucion correspondiente. Posteriormente, los especimenes fueron analizados antes y despues de cada inmersion usando un rugosimetro (Surfcorder SE 1700 KOZAKALAB), un microdurometro FM-700 (Future Tech), un microscopio Electronico de Barrido (MEB) (DSM 962-ZEISS) y una escala digital. Despues de los procedimientos de desinfeccion, los valores promedios obtenidos de cada analisis fueron evaluados estadisticamente. Las resinas para base de dentadura pueden ser vulnerables a los cambios de superficie cuando son inmersos en soluciones desinfectantes.

Palabras clave: Resina Acrilica; Desinfeccion; Dureza; Rugosidad.


 

INTRODUCTION

The awareness for the need of infection control in cross-contamination during dentistry procedures for patients, dentists and laboratory technicians has increased due to the prevalence of some infectious diseases such as AIDS and Hepatitis B1. When dental prostheses are repaired or adjusted in dental practice, they are contaminated with bacteria, viruses, and fungi2, due to inadequate disinfection of prostheses, the contamination of dental appliances and inadequate laboratory procedures before placing the prostheses in the mouth1,3,4. Potential sources of transmission of infectious diseases from patients to dental technicians include prostheses in contact with oral tissues, saliva and blood. When prostheses are removed from patients' mouths at various stages of trial and insertion, they may be contaminated by pathogenic organisms which can be transmitted through direct contact with the aerosol raised during trimming, finishing and polishing procedures5. The need to disinfect prostheses has resulted in the widespread search for disinfectant agents that are innocuous to the prosthesis surface. Various chemical agents are used in actual prosthesis disinfection, i.e. chlorine, iodophors, and aldehyde compounds6. Studies7,8 included immersion in 2% alkaline glutaraldehyde, 0.5% and 1% sodium hypochlorite, 3% aqueous formaldehyde, hydrogen peroxide as alternative methods of dental prosthesis disinfection. In addition, 1% sodium hypochlorite, 4% chlorhexidine gluconate and 3.78% sodium perborate proved to be effective in reducing the number of microorganisms on dental prostheses3,9. Chlorine dioxide (Alcide LD) is effective in eliminating microorganisms from the internal and external surface of acrylic resin10.
The importance of an infection control protocol in the dental laboratory is clear. Both the outer and inner surfaces of a dental prosthesis must be disinfected because they are both potential sources of contaminating microorganisms.Chau et al recommend 0.525% sodium hypochlorite solution for this kind of disinfection11. Several studies12-19 demonstrated that various disinfectants affect the physical properties of denture base resins such as hardness13,19 transverse strength14,16, roughness12,15 and deterioration on the surface of the denture resin14. The color stability of denture base resins can be significantly affected by disinfectant solutions such as glutaraldehyde, chlorhexidine, phenolic-based, alcohol-based and hypochlorite disinfectants13. The purpose of this study was to evaluate the hardness, roughness and mass loss of an acrylic denture base resin after in vitro exposure to three disinfectant solutions. A SEM analysis was also utilized to observe the surface topography.

MATERIALS AND METHODS

Forty acrylic resin specimens (Table 1) were constructed using a metallic cylindrical device made of copper and aluminum alloy, 2mm in height and 10mm in diameter. A mould was prepared with condensation silicone, to dense, soft consistency (Silon2 APS, Dentsply Ind. and Comercio Ltda., Petropolis, Brazil) and used to prepare twenty wax specimens. These wax specimens were placed in flasks (DCL number 6R, Dentaria Campineiro Ltda., Campinas, Brazil) as follows: dental stone type II was poured into the flask and 8 wax specimens were placed on the cast stone surface and covered with low-viscosity silicone (VIPI-SIL, VIPI., Pirassununga, Sao Paulo, Brazil). This impression material was placed in every retentive area of the wax specimens to optimize specimen preparation and removal.

Table 1: Description of the acrylic denture base resin used in this study.

The top part of the flask was completed with cast stone. After curing the cast stone and pressing, the flask was opened and wax specimens were removed, leaving the imprints in the silicone surface. Heat-cured acrylic resin (Classico, Artigos Odontologicos Ltda., Sao Paulo, Brazil) was prepared according to the manufacturer's recommendations, inserted in the plastic phase into the cast stone mold, and pressed gently and gradually in a hydraulic press to 1.25 t/pol2. An hour later, the flasks were transferred to a press with individual springs, and taken to the thermopolymerizing device1 for polymerization at 72oC for 12 hours. Following resin polymerization and cooling of the flasks at room temperature, the resin specimens were removed and finished with bars and through a sequence of SiC papers # 120, 400, 600, 800 and 1200, under coolant irrigation. Forty specimens were obtained and divided into 4 experimental groups according to the disinfectant solution (Table 2). To analyze mass loss (ML), all the samples were weighed before and after exposure to a disinfectant solution on a digital weighing scale to the nearest 0.1 mg (Bioprecisa, Eletronic Balance, FA2104N, Sao Paulo, Brazil), recording W1: weight before exposure to each solution and W2: weight after the procedure. The percentage of mass loss (ML) for each sample was calculated with the following equation: [W1- W2 /W1] X 1004, 5.

Table 2: Experimental groups, number (n) of samples and immersion time in the disinfectant solution.

Surface roughness was measured using a Surf Corder SE 1700 KOZAKALAB roughness meter (Ra), running perpendicular to the direction of finishing procedure at 2mm from the surface, at a speed of 0.1 mm/s. Three measurements were made and the arithmetic mean was calculated for each sample. The samples were submitted to a microhardness test using the Vickers indentation technique, with a microdurometer (FM-700, Future-Tech, Tokyo, Japan) (50gr load for 10s). Three indentations were made on each specimen, and the mean was taken as the microhardness value (HVN). Scanning Electronic Microscopy (SEM, DSM 962, Zeiss, Oberkochen, Germany) was employed to analyze the topography of the samples at 200x and 2000x. The assessed surfaces were cleaned in distilled water in an ultrasonic device during 10 minutes. After this procedure, the samples were placed on the aluminum cylinders ("stubs") and gold coated for observation by SEM.
Statistical analysis of the numerical data was performed by Analysis of Variance (ANOVA), Tukey's test (95% reliability level) and Dunnet's Simultaneous Test.

RESULTS

An exploratory data analysis was performed to determine the most appropriate statistical test. The mean and standard deviation values of the mass loss (ML), microhardness (HV), and roughness (Ra) are listed in Table 3.

Table 3: Means and standard deviations (SD) of mass loss (ML), microhardness (HV) and roughness (Ra).

The data were analyzed, separately, by One-way ANOVA (α<0.05) and Tukey's Test, considering three treatments and an additional treatment G1 (control group). Dunnet's test, a=0.05, was applied to compare the control mean with several treatment means. Mass loss results showed no significant differences (Dunnet's Simultaneous Test) between G2, G3, G4 and G1 (control group). For mass, One-Way ANOVA and Tukey's Test showed no significant differences between G2 and G4, but revealed statistically significant differences (α<0.05) between G3 and groups 2 and 4. (Tables 4 and 5).

Table 4: One-Way ANOVA for mass loss data obtained in experimental conditions.

Table 5: Comparison of averages, by Tukey's test for mass loss.

Hardness results showed no significant difference between G2, G3 and G4 and the control group (G1) with Dunnet's Simultaneous Test. One-Way ANOVA of microhardness data revealed no significant difference between the experimental groups tested. G2, G3 and G4 showed similar behavior to the control group. Dunnet's simultaneous t tests for roughness showed significant differences only between G2 and G1 (control group) but there was no difference between G2, G3 and G4. One-way ANOVA revealed no significant difference in mean roughness between G2, G3 and G4. Surface topography after immersion in the disinfection solutions showed different patterns of changes (Fig.1-4). The irregular surface produced by 2% glutaraldehyde, 1% sodium hypochlorite, 4% chlorhexidine solution is characterized by the presence of pores and defects.


Fig. 1
: Microphotography of the specimens immersed in distilled water (control group) magnified (a) 200x and (b) 2000x.


Fig. 2
: Microphotography of the specimens immersed in 2% glutaraldehyde magnified (a) 200x and (b) 2000x..


Fig. 3
: Microphotography of the specimens immersed in 1% sodium hypochlorite magnified (a) 200x and (b) 2000x.


Fig. 4
: Microphotography of the specimens immersed in 4% chlorhexidine magnified (a) 200x and (b) 2000x.

DISCUSSION

Reports in the literature using experimental testing protocols that would allow a comparison with this study are uncommon1,3,9,10. The purpose of immersing dental prostheses in a disinfectant solution is to inactivate infectious viruses and bacteria without damaging the dental prostheses. In this study, the disinfectant protocol was similar to others9,12,17,19 that exposed resin acrylic samples to disinfectant solutions: 1% and 2% sodium hypochlorite, 4% chlorhexidine and 2% glutaraldehyde. Similarly to this study, others1,3,5,9,12,13,19 evaluated the effects of disinfectant solutions on physical and mechanical properties of acrylic denture base resins, i.e. roughness, hardness and surface morphology15 20,21.
Roughness affects the patient's comfort and prosthesis longevity. A smoother surface leads to better esthetic results and less biofilm retention22. Several authors emphasized that irregular surfaces increase retention of the microorganisms and may affect oral health15,23-25. In this study, roughness values increased in the samples that were disinfected with 1% sodium hypochlorite in comparison to the control group, but did not differ from the other groups. Garcia et al.13 also observed surface changes in the samples that were submitted to disinfection and Machado et al.15 (2011) showed that roughness of hard reline material was affected by immersion in sodium perborate. Disinfectant agents may alter the surface of acrylic resins13,15. Current studies reveal that the samples immersed in sodium hypochlorite 1% showed a statistically significant increase in roughness compared to the control group. However, they did not differ from the other groups. The microhardness of the acrylic resins used as denture base immersed in disinfectant solutions was also evaluated in the present study, similarly to other studies1,9,13,20. Hardness is the property of a material that gives it the ability to resist permanent deformation (bending, breaking or shape changes), when a load is applied1.
The effect of disinfectant solutions on the microhardness of denture base after 60 minutes of immersion was observed. There was no statistically significant difference between the experimental groups and the control group, in keeping with other studies12 that reported no significant effect on the surfaces of the samples after 24 hours of immersion in 2% glutaraldehyde, 0.5% chlorhexidine and alcohol solutions. The same results were obtained when the acrylic resins used for denture base were disinfected in solutions such as chlorhexidine 4%, sodium hypochlorite 1% and sodium perborate for 10 minutes9. In addition, some studies reported the immersion of denture base in 2% alkaline glutaraldehyde for 1 hour, which resulted in no significant effect on hardness values1. Twelve-hour immersion in disinfectant solutions did not affect some of the physical properties of resin specimens19.
Surface morphology analyses showed changes in all the groups that were immersed in disinfectant solutions, mainly in samples immersed in sodium hypochlorite. Pore formation was observed in keeping with a study that used two glutaraldehyde disinfectant solutions, i.e. an alkaline solution and another alkaline solution with a phenolic buffer, and reported surface pitting and the formation of polymer beads after 10 minutes of exposure. When exposure time increased, the matrix phase seemed to dissolve slowly and more polymer beads were exposed19. Evaluation of mass loss of the acrylic resins following immersion for 1 hour in the disinfectant solutions glutaraldehyde 2%, chlorhexidine 4% and sodium hypochlorite 1%, for 1 hour revealed no statistically significant difference between the experimental and control groups. Nevertheless, samples immersed in glutaraldehyde solutions showed greater mass loss. Previous studies have reported mass loss following exposure of acrylic resins to disinfectant solutions. A decrease in weight would occur by water sorption. Signs of chemical attack were observed on the surface. These findings suggest that components of the disinfectant solution penetrate the resin base material and cause partial dissolution and softening of the surface19. Further studies will be necessary to examine how to minimize the damage of some kinds of disinfectant solutions on denture base acrylic resins.

CONCLUSIONS

The following conclusions can be drawn from this study: 1. Immersion of specimens in 1% sodium hypochlorite solution produced a significant increase in roughness. 2. No significant effect was observed on surface hardness of the tested specimens. 3. G3 mass loss values were higher than values in G2 and G4. 4. Qualitative evaluation by SEM showed varying degrees of surface change after immersion of the specimens in all the disinfectant solutions tested.

REFERENCES

1. Polyzois GL, Zissis AJ, Yannikakis SA. The effect of glutaraldehyde and microwave disinfection on some properties of acrylic denture resin. Int J Prosthodont 1995;8:150-154.         [ Links ]

2. Brace ML, Plummer KD. Practical denture disinfection. J Prosthet Dent 1993;70:538-540.         [ Links ]

3. Pavarina AC, Pizzolitto AC, Machado AL, Vergani CE, Giampaolo ET. An infection control protocol: effectiveness of immersion solutions to reduce the microbial growth on dental protheses. J Oral Rehabil 2003;30:532-536.         [ Links ]

4. Wakefield CW. Laboratory contamination on dental prostheses. J Prosthet Dent 1980;44:143-146        [ Links ]

5. Orsi IA, Andrade VG. Effect of chemical disinfectants on the transverse strength of heat-polymerized acrylic resins submitted to mechanical and chemical polishing. J Prosthet Dent 2004;92:382-388.         [ Links ]

6. Naylor WP. Infection control in fixed prosthodontics. Dent Clin North Am 1992;36:809-831.         [ Links ]

7. Powell GL, Runnels RD, Saxon BA, Whisenant BK. The presence and identification of organisms transmitted to dental laboratories. J Prosthet Dent 1990;64:235-237.         [ Links ]

8. Montagner H, Montagner F, Braun KO, Peres PE, Gomes BP. In vitro antifungal action of different substances over microwaved-cured acrylic resins. J Appl Oral Sci 2009; 17:432-435.         [ Links ]

9. Pavarina AC, Vergani CE, Machado LA,, Giampaolo ET, Teraoka MT. Effects of disinfectants solutions on the hardness of acrylic resin denture teeth. J Oral Rehabil 2003; 30: 749-752.         [ Links ]

10. Lin JJ, Cameron SM, Runyan DA, Craft DW. Disinfection of denture base acrylic resin. J Prosthet Dent 1999; 81:202- 206.         [ Links ]

11. Chau V B, Saunders TR, Pimsler M, Elfring DR. In-depth disinfection of acrylic resins. J Prosthet Dent 1995;74:309- 313.         [ Links ]

12. Asad T, Watkinson AC, Huggett R. The effects of various disinfectant solutions on surface hardness of an acrylic resin denture base material. Int J Prosthodont 1993;6:9-12.         [ Links ]

13. Rodrigues Garcia RC, Joane Augusto de S Jr, Rached RN, Del Bel Cury AA. Effect of denture cleansers on surface roughness and hardness of a microwave-cured acrylic resin and dental alloys. J Prosthodont 2004;13:173-178.         [ Links ]

14. Ma T, Johnson GH, Gordon GE. Effects of chemical disinfectants on the surface characteristics and color of denture resins. J Prosthet Den. 1997;77:197-204.         [ Links ]

15. Machado AL, Giampaolo ET, Vergani CE, Souza JF, Jorge JH. Changes in roughness of denture base and reline materials by chemical disinfection or microwave irradiation: surface roughness of denture base and reline materials. J Appl Oral Sci 2011;19:521-528.         [ Links ]

16. Goiato M., dos Santos DM, Moreno A, Iyda MG, Rezende MC, Haddad MF. Effect of disinfection and storage on the flexural strength of ocular prosthetic acrylic resins. Gerodontology 2012;29:e838-844.         [ Links ]

17. Orsi IA, Junior AG, Villabona CA, Fernandes FH, Ito IY. Evaluation of the efficacy of chemical disinfectants for disinfection of heat-polymerised acrylic resin. Gerodontology 2011;28:253-257        [ Links ]

18. Paranhos H de F, Davi LR, Peracini A, Soares RB. Lovato CH, Souza RF. Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions. Braz Dent J 2009;20:331-335.         [ Links ]

19. Shen C, Javid N.S, Colaizzi FA. The effect of glutaraldehyde base disinfectants on denture base resins. J Prosthet Dent. 1989;61:583-589.         [ Links ]

20. Neppelenbroek KH, Pavarina AC, Vergani CE, Giampaolo ET. Hardness of heat-polymerized acrylic resins after disinfection and long-term water immersion. J Prosthet Dent 2005;93:171-176.         [ Links ]

21. Anusavice K.J. Phillips Science of Dental Materials, 11th ed, Philadelphia Saunders Company, 2003;p.237.         [ Links ]

22. Ulusoy M, Ulusoy N, Aydin AK. An evaluation of polishing techniques on surface roughness of acrylic resins. J Prosthet Dent 1986;56:107-112.         [ Links ]

23. Kuhar M, Funduk N. Effects of polishing techniques on surface roughness of acrylic denture base resins. J Prosthet Dent. 2005;93:76-85.         [ Links ]

24. Rahal JS, Mesquita MF, Henriques GE, Nobilo MA. Surface roughness of acrylic resins submitted to mechanical and chemical polishing. J Oral Rehabil. 2004;31:1075-1079.         [ Links ]

25. Verran J, Maryan CJ. Retention of Candida Albicans on acrylic resin and silicone of different surface topography. J Prosthet Dent 1997;77:535-539.         [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons