SciELO - Scientific Electronic Library Online

 
vol.29 número2Oral health-related quality of life in the elderly population receiving health care at the public hospital network in Medellín, Colombia, and its related factorsSequential administration of alendronate and strontium ranelate: histomorphometry and bone biomechanics in ovariectomized animals índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Acta Odontológica Latinoamericana

versión On-line ISSN 1852-4834

Acta odontol. latinoam. vol.29 no.2 Buenos Aires set. 2016

 

ARTÍCULOS ORIGINALES

Masking ability of opaque thickness on layered metal-ceramic

 

Cari M. Pieper1, Renato F. A. Waldemarin2, Guilherme B. Camacho2

1 Private dental office in Pelotas, Rio Grande do Sul, Brazil; Logistics Battalion Brazilian Army Dental Service
2 Department of Restorative Dentistry, School of Dentistry – Federal University of Pelotas, Pelotas, Rio Grande do Sul , Brazil.

CORRESPONDENCE Dr. Renato Fabricio de Andrade Waldemarin Rua Goncalves Chaves, 457 CEP 96015560 Pelotas, RS, Brazil waldemarin@gmail.com


ABSTRACT

This study evaluated the masking ability of two opaques applied in different thicknesses. Eighty NiCr metal discs 16 mm in diameter and 1.0 mm thick were prepared. The disks were divided into 8 groups (n = 10). Ceramic opaque in paste (groups 1 to 4) or powder (groups 5 to 8) presentations were applied. They were machined with aluminum oxide burs to the following thicknesses: G1 and G5 = 0.10 mm; G2 and G6 = 0.15 mm; G3 and G7 = 0.20 mm and G4 and G8 = 0.30 mm. Dentin ceramic 0.7 mm thick was applied over these discs, sintered and glazed according manufacturer’s instructions. Color was assessed with a Minolta CR10 spectrocolorimeter on the CIELab scale. Powder opaque had higher values on (L) and (ΔE) variables, and lower values on (a) and (b) variables compared to paste opaque. For opaque thickness, 0.10 mm had higher ΔE than all other thicknesses. L values were higher for 0.20 mm and 0.30 mm. Lowest and highest a* values were observed for 0.10 mm and 0.30 mm, respectively. No difference was observed for b* values. There were differences between paste and powder opaque types; 0.10 mm thickness behaves differently from the other thicknesses, with higher ΔE, while 0.15 mm does not differ statistically from thicker layers.

Key words: Metal ceramic alloys; Ceramic; Dental porcelain; Color.

RESUMO

Capacidade de mascaramento de diferentes espessuras da camada opaca em cerâmica estratificada

O objetivo deste estudo foi avaliar a capacidade de mascara mento de duas cerâmicas opacas para metalocerâmicas aplicadas em espessuras diferentes. Foram confeccionados 80 discos metálicos de NiCr (High Bond) com 16 mm de diâmetro e 1,0 mm de espessura. Os discos foram divididos em 8 grupos (n=10) e aplicadas as cerâmicas opacas (Noritake) em pasta (grupos de 1 a 4) e em pó (grupos de 5 a 8). Estas foram usinadas com pontas de óxido de alumínio até atingir as seguintes espessuras: G1 e G5 = 0,10 mm; G2 e G6 = 0,15 mm; G3 e G7 = 0,20 mm e G4 e G8 = 0,30mm de espessura. A cerâmica de dentina opaca foi aplicada (0,7 mm) e realizado o glazeamento. A cor foi avaliada com Espectrocolorímetro (Minolta CR10) e foi aplicada análise de variância com para p<5%. Resultados: O opaco em pó apresentou valores maiores estaticamente significantes nas variáveis (L*) e (ΔE), ocorrendo o inverso nas outras duas variáveis. Quanto à espessura de opaco, os valores podem ser agrupados da seguinte forma, segundo os testes complementares aplicados: variável (L*): (0,10 = 0,15) < (0,20 = 0,30); variável (a*): (0,10) < (0,15 = 0,20) < (0,30); variável (b*): não houveram diferenças estatisticamente significantes; variável (ΔE): (0,10)< (0,15 = 0,20 = 0,30). Concluise que houve diferença entre os tipos de opaco em pasta e em pó e que todas as espessuras testadas, exceto a de 0,10 mm, podem ser usadas sem alteração significativa da cor.

Palavras Chave: Ligas metalocerâmicas; Cerâmica; Cor.


 

INTRODUCTION

A esthetic dental restorations have always been one of the major challenges in prosthetic and restorative dentistry1. Even when dentists request an adequate color for an indirect dental restoration, the result is not always satisfactory and there may be a significant difference in color, the cause of which is difficult to ascertain2. Despite the high acceptability and longevity of metalceramic, its aesthetics in anterior teeth are still a major challenge as a result of the underlying metal structure 3,4. To camouflage the metal, a layer of opaque porcelain about 0.3 mm thick is applied4, which affords masking ability due to its high metal oxide opacifier content.5 The most commonly used system for evaluating color change was established by CIE – Commission Internacionale de E’clairage in 19763. The CIE color system considers the light transmitted or reflected from an object. Since the CIE 1931 diagram did not have visual uniformity, mathema ticians changed the colors in order to facilitate color readings. This improved system, called CIEL*a*b* color space or CIELab1 color space can be used to study color in dental materials.
Previous studies have established the influence of each metalceramic layer on color and determined the influence of the layering pattern on the final color of dental restorations, concluding that the thickness of the layers affects the final color of a dental restoration 57. The opaque ceramic application method had also been studied, evaluating its bond strength and the final metalceramic color8. No visible differences have been found in the final porcelain color between application methods. Although many studies evaluate the effect of the thickness of different layers of opaque dentin on ceramic color, few studies show which thickness suffices to mask the underlying metal. The study of opaque layer thickness is clinically relevant because it influences the amount of tooth reduction necessary to make aesthetically appropriate metalceramic prostheses. The aim of this study is to evaluate whether there is a thickness lower than the recommended 0.3 mm which would have comparable masking ability, using a NiCr (High Bond) metal alloy and SuperPorcelain EX3 (Noritake) ceramic.

MATERIALS AND METHODS

Eighty circular wax discs 16 mm in diameter and 1.0 mm thick (Newwax, techNew) were obtained from a circular pattern and molded in phosphatebonded investment (Heat Shock, Polidental). NiCr discs (High Bond, Leona Industria e Comercio de Materiais e LigasOdontologicas e Medicas Ltda.) were obtained from these molds. The discs were removed from the molds, cleaned and sandblasted with 200 μm aluminum oxide particles to remove the excess covering and the oxide layer produced by the casting. Discs were manually sanded on both sides using 200 grit water sandpaper until they formed flat, but not polished, surfaces. The discs were left in ultrasonic baths for 10 minutes with distilled water to remove debris and dried with paper towels. Using a diamond drill (1012 KG Sorenson), four marks were made on the side of the discs at 90 degrees from one another. Guided by these marks, a digital caliper (Mitutoyo, Digimatic Caliper) was used to measure disc thickness. The specimens were randomly divided into 8 groups (n=10) to be covered in one of two opaque types: G1, G2, G3 and G4 paste opaque (Noritake paste opaque, Noritake, Kizao CO.) and G5, G6, G7 and G8 powder opaque (Super Porcelain EX3 Noritake Kizao CO.). Opaques were applied in the following thickness: G1 and G5 = 0.1 mm; G2 and G6 = 0.15 mm; G3 and G7 = 0.2 mm and G4 (control) and G8 = 0.3 mm. The discs were washed with distilled water in an ultrasonic bath and dried. Dentin opaque ceramic (Super Porcelain EX3 Color A3 or Noritake Kizao CO.) was applied in two layers, totaling 0.7 mm thick altogether. After obtaining the adequate dentin thickness, the discs were glazed. All the sintering steps were done according to the manufacturer’s recommendations. The color of the discs was measured with a portable spectro colorimeter (Minolta CR10) according to the CIEL*a*b* scale. The mean values of L*a*b* readings for G4 were used as control to calculate ΔE. Statistical analysis was performed on four variables (L*, a*, b* e ΔE), with two variation factors: opaque type (paste or powder) and opaque thickness (0.10 mm; 0.15 mm; 0.20 mm or 0.30 mm). All the variables fit the normal curve and homogeneity of errors. Under these circumstances, 2way ANOVA was performed, followed by posthoc Tukey´s test when needed, at 5% significance level.

RESULTS

Tables 1 to 3 show means and standard deviation (L*, a*, b* and ΔE respectively) and their grouping according to posthoc Tukey’s tests. For opaque type, Tables 1 to 4 show significant statistic differences for all variables. The (L*) and (ΔE) values in groups G5, G6, G7 and G8 were greater than in groups G1, G2, G3 and G4, the opposite being true for the other two variables.

Table 1. Means and standard deviation for L* values.

Table 2. Means and standard deviation for a* values.

Table 3. Means and standard deviation for b* values.

Concerning opaque thickness, the tables show that the values can be grouped as follows, according to the complementary tests applied: variable (L*): (0.10mm = 0.15mm) < (0.20mm = 0.30mm); variable (a*):(0.10mm) < (0.15mm = 0.20mm) < (0.30mm); variable (b*): there was no statistically significant difference, variable (ΔE): (0.10mm) < (0.15mm = 0.20mm = 0.30mm). Since the behavior of the two opaque types was different in all cases, a complementary statistical analysis was performed (ANOVA with a single variation factor – thickness) to see how the variable (ΔE) behaved for each opaque type separately (Table 5). The means and standard deviation values used in this analysis are the same as those shown in Table 4.

Table 4. Means and standard deviation for ΔE values.

Table 5. Grouping of ΔE values considering each opaque type separately.

Fig. 1 shows the respective curves for (ΔE) values according to opaque type and thickness.


Fig. 1
: ΔE values according opaque thickness.

DISCUSSION

The CIEL* a*b* scale was used, which represents color in a threedimensional space represented by axes L* (blackwhite axis), a* (greenred axis) and b* (blueyellow axis). The distance between any two points on this scale, represented by ΔE, can be obtained from the formula ΔE = (((L*1L* 2)2+(a*1a* 2)2+(b*1b* 2)2)0.5) 3,4,9.
The opaque type significantly influenced the color of metalceramics, since they presented significant differences for all variables tested (ΔE, L*, a* and b*). Although color perception is closely linked to variations in ΔE 2,3, 5,7,9-11 it is important to evaluate
the axes separately in order to understand which one contributed most to this color difference. The paste opaque was more uniform and easier to use than the powder opaque. Powder opaque tends to be more difficult to spread uniformly because of the presence of water, its surface tension and the contact angle between its surface and the metal. This may explain why paste is easier to apply, as well the differences found in all variables. Nevertheless, according to the intensity which each axis was affected, it is possible to say that the opaque type affects the “a*” axis more and the “L*” axis less, (Δa*=1.62; Δb*=1.21; ΔL*=0.62). The paste opaque presented greater redness and yellowness and was slightly less brilliant than the powder opaque. The presence of oxides tends to turn ceramic color green, and the lack of uniformity of powder opaque may lead to lower control of oxide formation, explaining this greater variation on the a* axis. Since the red color component is less present in teeth than the yellow component and variations in the red color are less tolerable than the yellow variations2, the main variation on axis “a*” is a very important factor when choosing the opaque type to be used. The ΔE values for paste are within the ΔE values considered little or not clinically noticeable (1 to 2), while the values for powder are within the limit of 2 to 3.3 ΔE units, considered perceptible, but clinically acceptable 9, 12-15. A change in the referential (control group) could lead to a change in the order of this observation. The results of our study differ from Waddell and Swain,8 who found no color difference according to the type of opaque used.
This difference may be due to the opaque/ ceramic system used or to the fact that Waddel and Swain used discs without metal substrate as control. Thicker opaque layers increased the values of “L*”, in contrast to other studies that used pure ceramic 16,17 or metalceramics 18, which stratified the dentin layer and not the opaque layer. Some studies found no (L*) variation from the opaque dentin layers 5, 7, 11. The lack of agreement with these studies may be explained considering that the metal used in the substructure turns dark after oxidation, and smaller, or more irregular, opaque layers tend to favor light absorption by this oxidized metal. As the metal becomes adequately covered by the opaque, light absorption is expected to decrease until it is stable at a certain value of L*. On the other hand, the dentin layer can lead to greater light scattering and/or light absorption by the pigment oxide particles present in it 4, 16. Variations in dentin and enamel thickness lead to variations in the final color of the ceramics and this was the reason why in this study it was chosen to add a simple opaque dentin layer 0.7 mm thick. Future studies can evaluate the effect of the opaque layer stratification in combination with stratification of the dentin and enamel layers to better understand the interference of these factors in the final color of metalceramic restorations. The variations in the values of a* represented a single axis where the values of 0.20 thickness differed from the values of 0.30 thickness. Generally the values of 0.30 thickness were more reddish than in 0.20 and 0.15 thicknesses; however, despite being statistically significant, this difference was in the order of 0.7 points, which constitutes color variation which is not noticeable per se. Although Douglas and Brewer2 report major perception capacity of changes in the red color component, they claim that these changes in the red component are noticeable just above 1.1 points, which did not usually happen between the 0.15 and 0.30 thicknesses. The results show that the paste opaque was even more effective in this aspect, because the component (a*) variations were at most 0.3 points between the 0.15 and 0.30 thicknesses. To calculate the values of ΔE, the average values of opaque paste L*a*b* of “0.30” thickness were used, because it is considered an adequate thickness for metalceramic dental restorations and because it is easier to cover with this opaque. It is relevant that on all axes, the 0.10 thickness differed from the others and thus presented higher ΔE than the control group. Other authors report the inability of a 0.10 mm layer to mask nonnoble metals 19 or metals with high palladium content 20,21, which is in agreement with our study. The observation that 0.20 mm opaque thickness is sufficient to mask the metal is consistent with previous findings 22, but differs from what the same author mentioned in another study, which found similarity only in the color 23. In our study, however, statistically, even 0.15 mm thickness can be considered the same as 0.30 mm thickness. This statement is particularly true to the paste opaque, where it is possible to graphically observe the stabilization of the ΔE value in all the thickness from 0.15. This graphic observation confirms the statistic result that the color variations from one 0.15 mm paste opaque thickness derive from the inherent variations in the making process of the metalceramic dental restoration and not from the thickness variation in the opaque layer, which are all below the 1 point perceptible limit. In a specific analysis on paste opaque, it is noteworthy that although there is a statistically significant difference between the 0.10 thickness and the others, ΔE for this thickness is within the range of not clinically perceptible (ΔE “0.10” =1.6), which is even more significant when we consider the color variation inherent to the ceramic production process found in the other thickness (e.g.: ΔE “0.30” = 0.95). In “0.10” thickness, and for this opaque type, color was affected most by the “L*” and “a*” axes. Future studies can ascertain whether the 0.10 mm thickness can be clinically acceptable when compared to the 0.30 mm thickness and/or if the addition of pigments can improve it at this thickness. For the powder opaque, however, it should be observed that the values of ΔE for “0.30” thickness differ from the ΔE values for “0.20” and “0.15” thicknesses, which are both the same. The data axes analysis, in particular, shows that the axis which contributed the most to this variation was the “a*” axis. Future studies can help elucidate whether the addition of red pigments to the powder opaque would enable its application in layers thinner than 0.30 mm, such as 0.20 mm and 0.1 5 mm. Some studies noted that the kind of metal used may change the color values in the metalceramic final restoration 14-16 as well as in the color of the opaque layer 19, 21, 24, 25. In this regard, our study has the limitation of having used only the NiCr alloy, which was chosen because it is a type of alloy very often used in the Brazilian market due to its low price. The influence of opaque type used combined with the metal variations may be the subject of a future study. Furthermore, and taking into consideration the limitations of our study, only the opaque dentin color was used (A3), without adding enamel. This decision was taken because earlier observations showed that thicker ceramic layers provide less noticeable background color, in this case, from the opaque layer, which is why we did not use enamel ceramic 4, 16. Another reason for not using more than one color or layering dentin/ enamel was to simplify the statistic model. Other studies may be necessary to clarify whether the stratification of these layers allows the use of the thickness mentioned or whether the 0.10 mm thickness is feasible with the stratification of the upper layers. Based on the experimental procedures performed and taking into consideration the limitations of this study, it is possible to conclude that: a) There is a difference between the powder and paste opaque; the paste opaque provides more predictable results than the powder opaque; b) The 0.10 mm thickness behaves differently from the other thickness, showing greater ΔE; the 0.10 mm thickness proved unsatisfactory for masking the metal substructure; c) The ΔE for 0.15 mm thickness is statistically the same as the others, showing that it is sufficient to mask the metal used in both ceramic systems.

ACKNOWLEDGEMENT

We thanks High Bond, Leona Industria e Comercio de Materiais e Ligas Odontologicas e Medicas Ltda the subsidy in alloy price.

REFERENCES

1. Goveia JC. Estudo colorimetrico da translucidez de materiais restauradores odontologicos [Dissertation]. Sao Paulo: University of Sao PauloUSP; 2004. URL: http://www.teses.usp.br/teses/disponiveis/23/23134/tde06062005163034/publico/GoveiaJC.pdf. Accessed in 2016/07/11        [ Links ]

2. Douglas RD, Brewer JD. Variability of porcelain color reproduction by commercial laboratories. J Prosthet Dent 2003; 90:339-346.         [ Links ]

3. Douglas RD, Przybylska M. Predicting porcelain thickness required for dental shade matches. J Prosthet Dent 1999; 82:143-149.         [ Links ]

4. Goodacre CJ. Designing tooth preparations for optimal success. Dent Clin North Am 2004; 48:359-385.         [ Links ]

5. Corciolani G, Vichi A, Louca C, Ferrari M. Influence of layering thickness on the color parameters of a ceramic system. Dent Mater 2010; 26:737-742.         [ Links ]

6. Fazi G, Vichi A, Corciolani G, Ferrari M. Spectrophotometric evaluation of color match to VITA classical shade guide of four different veneering porcelain systems for metal ceramic restorations. Am J Dent 2009; 22:19-22.         [ Links ]

7. Corciolani G, Vichi A, Louca C, Ferrari M. Color match of two different ceramic systems to selected shades of one shade guide. J Prosthet Dent 2011;105:171-176.         [ Links ]

8. Jorn D, Waddell JN, Swain MV. The influence of opaque application methods on the bond strength and final shade of PFM restorations. J Dent 2010; 38 Suppl 2:e143-149.         [ Links ]

9. Xu BT, Zhang B, Kang Y, Wang YN, Li Q. Applicability of CIELAB/CIEDE2000 formula in visual color assessments of metal ceramic restorations. J Dent. 2012; 40 Suppl 1:e39.         [ Links ]

10. Douglas RD, Steinhauer TJ, Wee AG. Intraoral determination of the tolerance of dentists for perceptibility and acceptability of shade mismatch. J Prosthet Dent. 2007; 97: 200-208.         [ Links ]

11. Corciolani G, Vichi A, Goracci C, Ferrari M. Colour correspondence of a ceramic system in two different shade guides. J Dent. 2009; 37: 98-101.         [ Links ]

12. Ragain JC Jr, Johnston WM. Minimum color differences for discriminating mismatch between composite and tooth color. J Esthet Restor Dent. 2001; 13: 41-48.         [ Links ]

13. Goiato MC, Zuccolotti BC, Moreno A, dos Santos DM, Pesqueira AA, Dekon SF. Colour change of soft denture liners after storage in coffee and coke. Gerodontology. 2011; 28:140-145.         [ Links ]

14. Imirzalioglu P, Karacaer O, Yilmaz B, Ozmen Msc I. Color stability of denture acrylic resins and a soft lining material against tea, coffee, and nicotine. J Prosthodont. 2010; 19:118-124.         [ Links ]

15. Ergun G, Nagas IC. Color stability of silicone or acrylic denture liners: an in vitro investigation. Eur J Dent. 2007; 1:144-151.         [ Links ]

16. Dozic A, Kleverlaan CJ, Meegdes M, van der Zel J, Feilzer AJ. The influence of porcelain layer thickness on the final shade of ceramic restorations. J Prosthet Dent. 2003; 90:56-3570.         [ Links ]

17. Ozturk O, Uludag B, Usumez A, Sahin V, Celik G. The effect of ceramic thickness and number of firings on the color of two allceramic systems. J Prosthet Dent 2008; 100:99-106.         [ Links ]

18. Jacobs SH, Goodacre CJ, Moore BK, Dykema RW. Effect of porcelain thickness and type of metalceramic alloy on color. J Prosthet Dent 1987; 57:138-145.         [ Links ]

19. Ozcelik TB, Yilmaz B, Ozcan I, Kircelli C. Colorimetric analysis of opaque porcelain fired to different base metal alloys used in metal ceramic restorations. J Prosthet Dent 2008; 99:193-202.         [ Links ]

20. Stavridakis MM, Papazoglou E, Seghi RR, Johnston WM, Brantley WA. Effect of different highpalladium metalceramic alloys on the color of opaque and dentin porcelain. J Prosthet Dent 2004; 92:170-178.         [ Links ]

21. Stavridakis MM, Papazoglou E, Seghi RR, Johnston WM, Brantley WA. Effect of different highpalladium metalceramic alloys on the color of opaque porcelain. J Prosthodont 2000; 9:71-76.         [ Links ]

22. Barghi N, Richardson JT. A study of various factors influencing shade of bonded porcelain. J Prosthet Dent 1978; 39:282-284.         [ Links ]

23. Barghi N, Lorenzana RE. Optimum thickness of opaque and body porcelain. J Prosthet Dent 1982; 48:429-431.         [ Links ]

24. Yilmaz B, Ozcelik TB, Wee AG. Effect of repeated firings on the color of opaque porcelain applied on different dental alloys. J Prosthet Dent 2009; 101:395-404.         [ Links ]

25. Ozcelik TB, Yilmaz B, Ozcan I, Wee AG. Color change during the surface preparation stages of metal ceramic alloys. J Prosthet Dent 2011; 106:38-47.         [ Links ]

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons